37332158376
Overview Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.

Specifications

Additional Information

  • UPC: 37332158376
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Monitored
  • Output Capacity Details: 11.5kW (415/240V), 11.1kW (400/230V), 10.5kW (380/220V) total capacity; 16A max per output phase (L1-L2, L2-L3, L3-L1); 16A max per C19 outlet; 10A max per C13 outlet
  • Frequency Compatibility: 50 / 60 Hz
  • Output Receptacles: (30) C13; (6) C19
  • Output Nominal Voltage: 220 (380V input); 230 (400V input)
  • Overload Protection: n/a
  • PDU Input Voltage: 380; 400
  • Recommended Electrical Service: 16A 400/230V with IEC309 16A Red (3P+N+E) outlet
  • Maximum Input Amps: 16
  • PDU Plug Type: IEC-309 16/20A RED (3P+N+E)
  • Input Cord Length (ft.): 3
  • Input Phase: 3-Phase
  • Reported Load Segments: Supports local monitoring of current for each output phase (16A balanced max per output load banks L1, L2 and L3); BANK "L1" is powered by L1-N (outlets 1-12); BANK "L2" is powered by L2-N (outlets 13-24); BANK "L3" is powered by L3-N (outlets 25-36)
  • Front Panel LCD Display: Digital display reports output load level in amps separately for each output phase; Can also be used to scroll the configured IP address
  • Front Panel LEDs: Set of 3 LEDs (L1, L2, L3) indicate the output load segment the digital current display is reporting
  • Switches: SELECT switch advances the digital display and LED to report power consumption for load segments L1, L2 and L3 (short press); SELECT switch also rotates the local display 90 degrees for overhead power input (long press); SCROLL IP button scrolls the configured IP address (long press)
  • Shipping Dimensions (hwd / in.): 7.2 x 9.65 x 75.9
  • Shipping Weight (lbs.): 17.8
  • Unit Dimensions (hwd / in.): 70 x 2.19 x 3.58
  • Unit Weight (lbs.): 12.6
  • Material of Construction: Metal
  • Form Factors Supported: Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
  • PDU Form Factor: 0U; Vertical
  • Storage Temperature Range: 5 to 122F (-15 to 50C)
  • Relative Humidity: 5 to 95% non-condensing
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • TAA Compliant Option: TAA Compliant Version Available - Order Tripp LitePDU3XVN3G16TAA
  • Certifications: Tested to CE (EN 60950-1), Class A (Emissions), RoHS (Hazardous Substances)
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932906.pdf","title":"Owner's Manual for High Voltage 3-Phase PDU 932906 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/PDU3XVN3G16-PDU3XVN10G16-Submittal-Drawing-EN.pdf","title":"Submittal Drawings"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/230V-PDU-Specification-Brochure-EN.pdf","title":"230V Power Distribution Unit (PDU) Specification Brochure 9533FF (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-monitored-pdus\/75342","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-monitored-pdus\/75342"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4724","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/11kw-3-phase-monitored-pdu-220-230v-30-c13-6-c19-iec-309-16a-red-380-400v-input-3ft-cord-0u-vertical~PDU3XVN3G16/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite 3 phase Monitored PDU \/ Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip."

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...