SmartOnline 208/240V 10kVA 9kW Double-Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA
$4,470.41

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU10000RT3U
Sku:
176895
UPC:
37332127372
Overview Tripp Lite SU10000RT3U 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

Specifications

Additional Information

  • UPC: 37332127372
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 10000
  • Output kVA Capacity (kVA): 10
  • Output Watt Capacity (Watts): 9000
  • Output kW Capacity (kW): 9.0
  • Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
  • Power Factor: 0.9
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 200V; 208V; 240V
  • Nominal Voltage Details: Voltage selection via front panel LCD interface
  • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
  • Frequency Compatibility Details: Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (No de-rating); Output frequency regulation +/- 0.05Hz (free running)
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: (4) L6-20R; (2) L6-30R
  • Output Circuit Breakers: 20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlet each
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)
  • Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 240V AC
  • UPS Input Connection Type: Hardwire
  • UPS Input Connection Description: 3 wire single phase input (L1, L2, G)
  • Recommended Electrical Service: 60A
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 4.3 min. (9000w)
  • Half Load Runtime (min.): 12.5 min. (4500w)
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
  • External Battery Pack Compatibility: BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH
  • DC System Voltage (VDC): 240
  • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 90% (typical, full load discharge)
  • Battery Replacement Description: Hot-swappable, user replaceable external battery packs
  • Expandable Runtime: Yes
  • Voltage Regulation Description: 2% output voltage regulation in standard online, double-conversion mode
  • Overvoltage Correction: Corrects overvoltages up to 300V
  • Undervoltage Correction: Corrects undervoltages as low as 100V
  • Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
  • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
  • Alarm Cancel Operation: Alarm cancel switch
  • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
  • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Included Mounting Accessory Description: 2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD)
  • Optional Mounting Accessory Notes: 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 5.14 x 17.5 x 25.82
  • Rack Height (U Spaces): 6
  • Maximum Device Depth (in.): 32.5
  • Minimum Required Rack Depth (inches): 37.5
  • UPS Power Module Weight (lbs.): 43
  • UPS Power Module Weight (kg): 19.50
  • UPS Dimensions Details: Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
  • Included Battery Pack Dimensions (hwd / in.): 5.25 x 17.5 x 25
  • Included Battery Pack Weight (lbs.): 158.7
  • UPS Shipping Dimensions (hwd / in.): 27 x 42 x 45
  • Shipping Weight (lbs.): 300
  • Cooling Method: Fan
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 952
  • Primary UPS Height (mm): 131
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 656
  • Shipping Height (mm): 686
  • Shipping Width (mm): 1067
  • Shipping Depth (mm): 1143
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 3415
  • AC Economy Mode BTU / Hr. (Full Load): 1280
  • Battery Mode BTU / Hr. (Full Load): 4593
  • AC Mode Efficiency Rating (100% Load): 91%
  • AC Economy Mode Efficiency Rating (100% Load): 96%
  • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
  • Audible Noise: 60 dBA at front side 1 meter
  • Operating Elevation (msnm): 0-3000 m
  • Communications Interface: USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB, DB9 serial and EPO cables included
  • WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Transfer Time (Economy Mode): 8 ms. typical power failure response in optional economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): 100V
  • High Voltage Transfer to Battery Power (Setpoint): 300V
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • Economy Mode Operation: Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
  • Green Energy-Saving Features: High efficiency economy mode operation; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A (EMI)
  • UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932897.pdf","title":"Owner's Manual for SmartOnline 8kVA-10kVA UPS 932897 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU10000RT3U-Runtime-Chart-EN.pdf","title":"SU10000RT3U runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other\/case-study\/Whiteriver-School-District-Casestudy-EN.pdf","title":"Whiteriver Unified School District Case Study (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other\/case-study\/Andover-Case-Study.pdf","title":"Andover Public Schools Case Study - VoIP Network Protection (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932487.PDF","title":"Owner's Manual for BP Battery 932487 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/su10000rt3u-smartonline-ups-system\/60540","title":"https:\/\/www.tripplite.com\/video\/su10000rt3u-smartonline-ups-system\/60540"},{"url":"https:https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731","title":"https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731"},{"url":"https:https:\/\/www.tripplite.com\/video\/8-10kva-smartonline-ups-hot-swap-demo\/45730","title":"https:\/\/www.tripplite.com\/video\/8-10kva-smartonline-ups-hot-swap-demo\/45730"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/3211","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240v-10kva-9kw-double-conversion-ups-6u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial-bypass-switch-nema-outlets~SU10000RT3U/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite SU10000RT3U 10,000VA \/ 10kVA \/ 9000 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations."