Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

7.4kW Single-Phase Switched PDU, 230V Outlets (20 C13, 4 C19), IEC309 32A Blue, 10ft Cord, 0U Vertical, TAA Compliant
$711.63

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PDUMV32HVNET
Sku:
158743
UPC:
37332153968
Overview Tripp Lite Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.

Specifications

Additional Information

  • UPC: 37332153968
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Switched
  • Output Capacity Details: 7.7kW (240V), 7.4kW (230V), 7kW (220V), 6.7kW (208V), 6.4kW (200V) / 32A total capacity; 16A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet
  • Frequency Compatibility: 50 / 60 Hz
  • Output Receptacles: (20) C13; (4) C19
  • Output Nominal Voltage: 230
  • Overload Protection: Two 20A circuit breakers protect 12 outlets each
  • Customized Load Management Receptacles: Each outlet is individually controllable via remote interface
  • PDU Input Voltage: 230
  • Recommended Electrical Service: 32A 230V
  • Maximum Input Amps: 32
  • PDU Plug Type: IEC-309 32A BLUE (2P+E)
  • Input Cord Length (ft.): 10
  • Input Phase: Single-Phase
  • Front Panel LCD Display: Digital display reports output amps in 3 separately metered loading segments (BANK 1: Outlets #1-12; BANK 2: Outlets #13-24; BANK 3: All outlets combined)
  • Front Panel LEDs: 24 power availability LEDs confirm power off/on status for each built-in outlet
  • Switches: Pushbutton control scrolls visual load meter display from bank 1, bank 2 and band 1&2 combined
  • Shipping Dimensions (hwd / in.): 4 x 6 x 72.5
  • Shipping Weight (lbs.): 16.5
  • Unit Dimensions (hwd / in.): 70 x 2.19 x 4.75
  • Unit Weight (lbs.): 11.5
  • Form Factors Supported: 0U vertical rackmount. Includes mounting brackets. Supports toolless mounting in button-mount compatible racks
  • PDU Form Factor: 0U; Vertical
  • Relative Humidity: 5-95% non-condensing
  • SNMP Compatibility: Yes, pre-installed SNMPWEBCARD provides remote monitoring via web, telnet, and SNMP management systems. Remote management gives user ability to turn connected loads on or off individually
  • Certifications: Tested to CE, IEC/EN60950, TAA Compliant
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932721.pdf","title":"Owner's Manual for Switched Rack PDUs 932721"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/Tripp-Lite-PDUMV32HVNET-Application-Bulletin-EN.pdf","title":"Submittal Drawings"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/230V-PDU-Specification-Brochure-EN.pdf","title":"230V Power Distribution Unit (PDU) Specification Brochure 9533FF (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4535","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/7.4kw-single-phase-switched-pdu-230v-outlets-20-c13-4-c19-iec309-32a-blue-10ft-cord-0u-vertical-taa-compliant~PDUMV32HVNET/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite Switched PDU \/ Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is displayed locally via visual meter and remotely via web\/network interface to warn of potential overloads before critical IT mains or branch breakers trip."
  • List price: No