Overview Tripp Lite's SU20KX (20kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with 1+1 parallel capability. In 1+1 configuration, two SU20KX models connected in parallel can provide fail-safe redundancy (two 20kVA models supporting a 20kVA load) or increased capacity (two 20kVA models supporting an 40kVA load). The SU20KX provides mission-critical equipment with the highest level of power protection available. Large capacity 20,000VA/16,000W UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time assures compatibility with all equipment types. High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce less than 3% input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load (1:1 ratio). Extremely efficient operation (up to 97%) saves money by lowering electricity consumption. Hardwire input and output connections. The SU20KX features 50 or 60 Hz (auto-selectable) frequency. The SU20KX combines internal power and battery modules in a single small-footprint tower compartment. Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C, available separately). A manual bypass breaker and an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance.

Specifications

Additional Information

  • UPC: 37332141354
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 20000
  • Output kVA Capacity (kVA): 20
  • Output Watt Capacity (Watts): 16000
  • Output kW Capacity (kW): 16
  • Power Factor: 0.8
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
  • Frequency Compatibility: 50 / 60 Hz
  • Frequency Compatibility Details: Automatic frequency selection
  • Output Voltage Regulation (Line Mode): +/-1%
  • Output Voltage Regulation (Battery Mode): +/-1%
  • Output Receptacles: Hardwire
  • Output AC Waveform (AC Mode): Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 28A / 29A / 30A
  • Nominal Input Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
  • Nominal Input Voltage Description: 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
  • UPS Input Connection Type: Hardwire
  • Input Phase: 3-Phase
  • Full Load Runtime (min.): 5.5 min. (16kw)
  • Half Load Runtime (min.): 13 min. (8kw)
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
  • External Battery Pack Compatibility: BP480V200; BP480V26B; BP480V300; BP480V400; BP480V40C; BP480V500
  • Expandable Runtime Description: External battery pack wiring is contractor supplied
  • DC System Voltage (VDC): +/- 240VDC
  • Internal UPS Replacement Battery Cartridge: SURBC2030
  • Battery Replacement Description: Hot-swappable, replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal
  • Undervoltage Correction: Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye)
  • Switches: ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables Bypass output
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
  • Audible Alarm: Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more
  • LED Indicators: 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Joule Rating: 5950
  • AC Suppression Response Time: Instantaneous
  • Installation Form Factors Supported with Included Accessories: Tower
  • Primary Form Factor: Tower
  • UPS Power Module Dimensions (hwd, in.): 46 x 20.5 x 33.7
  • UPS Power Module Weight (lbs.): 588.6
  • UPS Power Module Weight (kg): 266.98
  • UPS Shipping Dimensions (hwd / in.): 55 x 28.5 x 42.5
  • Shipping Weight (lbs.): 738.5
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Primary UPS Height (mm): 1168
  • Primary UPS Width (mm): 521
  • Primary UPS Depth (mm): 856
  • Shipping Height (mm): 1397
  • Shipping Width (mm): 724
  • Shipping Depth (mm): 1080
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 3053
  • Battery Mode BTU / Hr. (Full Load): 3488
  • Communications Interface: DB9 Serial; Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: DB9 cabling included
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Low Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power
  • High Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire, wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
  • Green Energy-Saving Features: High efficiency economy mode operation; Schedulable daily hours of economy mode operation
  • UPS Certifications: CE
  • Product Warranty Period (International): 2-year limited warranty
  • Product Warranty Period (Mexico): 1-year limited warranty
  • Product Warranty Period (Puerto Rico): 2-year limited warranty

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-20kva-16kw-modular-3-phase-ups-system-double-conversion-ups-snmpwebcard-option-db9-serial~SU20KX/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite's SU20KX (20kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with 1+1 parallel capability. In 1+1 configuration, two SU20KX models connected in parallel can provide fail-safe redundancy (two 20kVA models supporting a 20kVA load) or increased capacity (two 20kVA models supporting an 40kVA load). The SU20KX provides mission-critical equipment with the highest level of power protection available. Large capacity 20,000VA\/16,000W UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time assures compatibility with all equipment types. High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce less than 3% input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load (1:1 ratio). Extremely efficient operation (up to 97%) saves money by lowering electricity consumption. Hardwire input and output connections. The SU20KX features 50 or 60 Hz (auto-selectable) frequency. The SU20KX combines internal power and battery modules in a single small-footprint tower compartment. Typical half-load\/full-load runtimes are 13 min.\/5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C, available separately). A manual bypass breaker and an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance."