SVX180KL
Overview Tripp Lite's SVX180KL 180kVA / 180kW SmartOnline large-chassis UPS includes installed Input, Bypass and Output breakers, a Static Transfer Switch (STS) and 6 included 30kVA SVX30PM power modules. The system includes space for up to 2 additional user installable SVX30PM power modules to accommodate increased capacity up to 210kW with N+1 fault-tolerance. Featuring modular, scalable design with high efficiency voltage and frequency independent / VFI operation, Tripp Lite's SVX Series SmartOnline UPS systems are ideal for the protection of a wide variety of critical IT systems. Scalable, modular configuration enables UPS capacity upgrades and hot-swap power supply maintenance without costly downtime. Over 94% efficient in standard online-mode and over 98% efficient in optional economy-mode enables reduced operating and cooling costs. Unity power factor configuration provides equal kVA and kW output ratings for up to 25% more wattage capacity than common 0.8 - 0.9 power factor competing designs. Network-grade sine-wave AC output with 1% output voltage regulation and less than 1.5% output total harmonic distortion. Advanced IGBT inverter with Digital Signal Processor (DSP) technology provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing. Dual input hardwire design enables operation from one or two input power sources for enhanced system availability. N+1 fault-tolerance is supported anytime there is an "extra" SVX30PM 30kW power module installed beyond the minimum required quantity. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. UPS batteries are not included, External 240VDC battery cabinets sold separate.

Specifications

Additional Information

  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 180000
  • Output kVA Capacity (kVA): 180
  • Output Watt Capacity (Watts): 180000
  • Output kW Capacity (kW): 180
  • Output Capacity Details: OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
  • Power Factor: 1.0
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
  • Nominal Voltage Details: Output THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: 50mV; Max Phase angle deviation: 2; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
  • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
  • Frequency Compatibility Details: Auto-selectable, user adjustable
  • Output Receptacles: Hardwire
  • Output Circuit Breakers: 400A 3 pole magnetic breaker
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Output Voltage Regulation: ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 220/230/240V 1% typical (balanced load); 2% typical (unbalanced load); ECONOMY MODE: 220/230/240V 15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)
  • Output Frequency Regulation: ONLINE MODE: Output frequency is 0.05Hz of input frequency when input is within 4Hz* of the configured 50/60Hz output setting; Output frequency is 0.05Hz the configured 50/60Hz output setting when input is outside 4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is 0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is 0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to 4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to 4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to 4Hz and is user adjustable to 1Hz, 2Hz or 4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes
  • Output Amp Capacity: Output Amp Capacity 273A (220/380V); 260A (230/400V); 250A (240/415V)
  • Modular Upgrade Options: Includes 6 SVX30PM 30kVA power modules. Up to 2 additional SVX30PM 30kVA power modules can be added for additional capacity or N+1 availability; Add 1 SVX30PM for 210kVA capacity (or 180kVA with N+1 redundancy); Add 2 SVX30PM for 210kVA capacity with N+1 redundancy
  • Rated input current (Maximum Load): SVX180KL 180kVA Configuration: 330A; Maximum 210kVA Large Chassis Configuration: 385A; 40A maximum inrush current
  • Nominal Input Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
  • Nominal Input Voltage Description: Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources
  • UPS Input Connection Type: Hardwire
  • Input Circuit Breakers: MAIN and ALTERNATE AC inputs are each protected by 400A 3 pole magnetic breakers
  • Input Phase: 3-Phase
  • Input Frequency: 40 to 70Hz (online mode); 50/60Hz Auto-selectable
  • Power Factor (Input): Greater than 0.99 (full load)
  • THDi: Less than 3% (full linear load)
  • Full Load Runtime (min.): Batteries sold separate; Runtime is dependent on battery pack quantity and load level
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs; 100A 3 pole 250VDC breaker recommended for external battery
  • Expandable Runtime Description: External battery pack wiring is contractor supplied
  • DC System Voltage (VDC): 240VDC
  • Battery Recharge Rate (Included Batteries): User selectable charging current of 1A to 8A (2A factory setting); Recharge rate is dependent on number of external battery packs connected and the selected charge current setting
  • Battery Replacement Description: Hot-swappable, replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: Maintains continuous output in online mode, without using battery power, during overvoltages to 478V (Ph-Ph), reducing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage
  • Undervoltage Correction: Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 305V (Ph-Ph) at full load and to 208V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage
  • Front Panel LCD Display: 145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
  • Switches: Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
  • Alarm Cancel Operation: Audible alarms can be muted using on-screen prompts
  • Audible Alarm: Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
  • LED Indicators: Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Joule Rating: 2496
  • AC Suppression Joule Rating Details: 2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)
  • AC Suppression Response Time: Instantaneous
  • Installation Form Factors Supported with Included Accessories: Tower
  • Primary Form Factor: Tower
  • UPS Power Module Dimensions (hwd, in.): 79.13 x 23.62 x 43.3
  • UPS Power Module Weight (lbs.): 1058
  • UPS Power Module Weight (kg): 479.90
  • UPS Shipping Dimensions (hwd / in.): 85.62 x 29.52 x 48.03
  • Shipping Weight (lbs.): 1240
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Primary UPS Height (mm): 2010
  • Primary UPS Width (mm): 600
  • Primary UPS Depth (mm): 1100
  • Shipping Height (mm): 2175
  • Shipping Width (mm): 750
  • Shipping Depth (mm): 1220
  • Operating Temperature Range: 0 to +40C (+32 to +104F); De-rates to 90% capacity at 35C / 95F and 80% capacity at 40C / 104F
  • Storage Temperature Range: -15 to +60C (+5 to +140F)
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 33166
  • AC Economy Mode BTU / Hr. (Full Load): 5078
  • AC Mode Efficiency Rating (100% Load): 95%
  • AC Economy Mode Efficiency Rating (100% Load): 99%
  • Audible Noise: Audible Noise Less than 73 DBA front-side, 1m
  • Operating Elevation (msnm): Operating Elevation (m) Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)
  • Communications Interface: DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
  • Network Management Cards: WEBCARDLX
  • Network Monitoring Port Description: Includes pre-installed Tripp Lite WEBCARDLX network interface
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: DB9 cabling included
  • SNMP Compatibility: SNMP Compatibility Includes pre-installed WEBCARDLX network interface card
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during brownout/undervoltage conditions to 305V (Ph-Ph) Full load or 208V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power
  • High Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during overvoltages to 478V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module
  • Green Energy-Saving Features: Greater than 95% efficiency - GREEN UPS; High efficiency economy mode operation; Schedulable daily hours of economy mode operation
  • UPS Certifications: CE; ROHS (Restriction of Hazardous Substances)
  • UPS Certification Details: Agency standards IEC 62040-1:2008+A1:2013; EMI Approvals EN62040-2, 2006 (Category C3); Vibration and Shock: SS-EN 60068-2-64
  • Product Warranty Period (International): 2-year limited warranty

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-svx-series-180kva-modular-scalable-3-phase-on-line-double-conversion-400-230v-50-60hz-ups-system~SVX180KL/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite's SVX180KL 180kVA \/ 180kW SmartOnline large-chassis UPS includes installed Input, Bypass and Output breakers, a Static Transfer Switch (STS) and 6 included 30kVA SVX30PM power modules. The system includes space for up to 2 additional user installable SVX30PM power modules to accommodate increased capacity up to 210kW with N+1 fault-tolerance.\n\nFeaturing modular, scalable design with high efficiency voltage and frequency independent \/ VFI operation, Tripp Lite's SVX Series SmartOnline UPS systems are ideal for the protection of a wide variety of critical IT systems. Scalable, modular configuration enables UPS capacity upgrades and hot-swap power supply maintenance without costly downtime. Over 94% efficient in standard online-mode and over 98% efficient in optional economy-mode enables reduced operating and cooling costs. Unity power factor configuration provides equal kVA and kW output ratings for up to 25% more wattage capacity than common 0.8 - 0.9 power factor competing designs. Network-grade sine-wave AC output with 1% output voltage regulation and less than 1.5% output total harmonic distortion. Advanced IGBT inverter with Digital Signal Processor (DSP) technology provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing. Dual input hardwire design enables operation from one or two input power sources for enhanced system availability. N+1 fault-tolerance is supported anytime there is an \"extra\" SVX30PM 30kW power module installed beyond the minimum required quantity. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. UPS batteries are not included, External 240VDC battery cabinets sold separate."