Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartPro 120V 1.5kVA 1kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets
$409.99

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SMC15002URM
Sku:
712451
UPC:
0037332186249
Overview The SMC15002URM SmartPro 120V 1.5kVA 1kW Line-Interactive Sine Wave UPS provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up high-performance workstations, servers and network equipment, the SMC15002URM switches to battery mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss. Pure sine wave output is compatible with active power factor correction (PFC) power supplies. Featuring eight NEMA 5-15R outlets and a 10-foot power cord with 120V NEMA 5-15P input, the SMC15002URM has an internal battery that provides 17.7 minutes of support at half load and 6.5 minutes at full load. A front-panel LCD screen lets you configure settings and monitor operating data, such as load level, voltage, battery charge and estimated runtimes. Automatic voltage regulation (AVR) maintains 120V nominal output over an input range of 83V to 147V without using battery power. EMI/RFI noise filtering improves your equipments performance and prevents damage. A 570-joule surge suppression rating protects your equipment from harmful power surges. With Tripp Lites free downloadable PowerAlert software, SMC15002URM enables safe unattended system shutdown and file saves in case of a prolonged power failure.

Specifications

Additional Information

  • UPC: 0037332186249
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 1500
  • Output kVA Capacity (kVA): 1.5
  • Output Watt Capacity (Watts): 1000
  • Output kW Capacity (kW): 1.0
  • Nominal Output Voltage(s) Supported: 110V; 115V; 120V
  • Nominal Voltage Details: 120v nominal output in battery mode
  • Frequency Compatibility: 60 Hz
  • Output Voltage Regulation (Line Mode): -21%, +8%
  • Output Voltage Regulation (Battery Mode): +/- 5%
  • Output Receptacles: (8) 5-15R
  • Output AC Waveform (AC Mode): Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 12A
  • Nominal Input Voltage(s) Supported: 120V AC
  • UPS Input Connection Type: 5-15P
  • Input Circuit Breakers: 15A
  • UPS Input Cord Length (ft.): 10
  • Recommended Electrical Service: 15A 120V
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 6.5 min. (1000w)
  • Half Load Runtime (min.): 17.7 min. (500w)
  • DC System Voltage (VDC): 36
  • Battery Recharge Rate (Included Batteries): Less than 4.5 hours from 10% to 90% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: RBC93-2U
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: No
  • Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
  • Overvoltage Correction: Input voltages between 128 and 147 are reduced by 12%
  • Undervoltage Correction: Input voltages between 83 and 107 are boosted by 14%
  • Front Panel LCD Display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
  • Switches: 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
  • Alarm Cancel Operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
  • Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
  • UPS AC Suppression Joule Rating: 570
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Included Mounting Accessory Description: Includes UPSHDEARKIT for 2 point front-mount and 2 point center-mount rackmount installation in 2 and 4 post racks, plus wallmount installation
  • Installation Form Factors Supported with Optional Accessories: 4 post rackmount(4POSTRAILKIT); Tower(2-9USTAND); Wallmount(2POSTRMKITWM)
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 3.45 x 17.3 x 13.45
  • Rack Height (U Spaces): 2
  • Minimum Required Rack Depth (inches): 16.5
  • UPS Power Module Weight (lbs.): 46.5
  • UPS Power Module Weight (kg): 21.09
  • UPS Shipping Dimensions (hwd / in.): 8.8 x 20 x 23.5
  • Shipping Weight (lbs.): 58.5
  • Cooling Method: Fan
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 419
  • Primary UPS Height (mm): 88
  • Primary UPS Width (mm): 439
  • Primary UPS Depth (mm): 342
  • Shipping Height (mm): 224
  • Shipping Width (mm): 508
  • Shipping Depth (mm): 597
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 223
  • Battery Mode BTU / Hr. (Full Load): 650
  • AC Mode Efficiency Rating (100% Load): 94%
  • Operating Elevation (ft.): 0-3000M (0-10,000 Ft)
  • Audible Noise: 45 dBA max at 1m frontside
  • Operating Elevation (msnm): 0 - 3000 m
  • Communications Interface: DB9 Serial; EPO (emergency power off); USB
  • Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB cabling included
  • WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
  • Network UPS Tools Compatibility: NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
  • Transfer Time: 5 milliseconds (AC to battery), 1 milliseconds (Battery to AC)
  • Low Voltage Transfer to Battery Power (Setpoint): 83
  • High Voltage Transfer to Battery Power (Setpoint): 147
  • Grounding Lug: Back panel grounding lug
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Hot swappable batteries
  • UPS Certifications: Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
  • Product Warranty Period (Worldwide): 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartpro-120v-1.5kva-1kw-line-interactive-sine-wave-ups-2u-rack-tower-lcd-usb-db9-8-outlets~SMC15002URM/
  • Packaging

  • Certifications

  • Details: "Overview\nThe SMC15002URM SmartPro 120V 1.5kVA 1kW Line-Interactive Sine Wave UPS provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up high-performance workstations, servers and network equipment, the SMC15002URM switches to battery mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss. Pure sine wave output is compatible with active power factor correction (PFC) power supplies.\n\nFeaturing eight NEMA 5-15R outlets and a 10-foot power cord with 120V NEMA 5-15P input, the SMC15002URM has an internal battery that provides 17.7 minutes of support at half load and 6.5 minutes at full load. A front-panel LCD screen lets you configure settings and monitor operating data, such as load level, voltage, battery charge and estimated runtimes.\n\nAutomatic voltage regulation (AVR) maintains 120V nominal output over an input range of 83V to 147V without using battery power. EMI\/RFI noise filtering improves your equipments performance and prevents damage. A 570-joule surge suppression rating protects your equipment from harmful power surges. With Tripp Lites free downloadable PowerAlert software, SMC15002URM enables safe unattended system shutdown and file saves in case of a prolonged power failure."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...