Overview Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.

Specifications

Additional Information

  • UPC: 37332158215
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Monitored
  • Output Capacity Details: 5.7kW (208V) total capacity / 9.2A max per output phase (L1-L2, L2-L3, L3-L1)
  • Frequency Compatibility: 50 / 60 Hz
  • Output Receptacles: (30) C13; (6) C19
  • Output Nominal Voltage: 208
  • Overload Protection: n/a
  • PDU Input Voltage: 208
  • Recommended Electrical Service: 20A 208V with NEMA L15-20R outlet
  • Maximum Input Amps: 16
  • PDU Plug Type: NEMA L15-20P
  • Input Cord Details: Cord length specifications are nominal and subject to manufacturing variance
  • Input Cord Length (ft.): 3
  • Input Phase: 3-Phase
  • Reported Load Segments: Supports local monitoring of current for each output phase (9.2A max per L1-L2, L2-L3, L3-L1 balanced); BANK "L1" is powered by L1-L2 (outlets 1-12); BANK "L2" is powered by L2-L3 (outlets 13-24); BANK "L3" is powered by L3-L1 (outlets 25-36)
  • Front Panel LCD Display: Digital display reports output load level in amps separately for each output phase; Can also be used to scroll the configured IP address
  • Front Panel LEDs: Set of 3 LEDs (L1, L2, L3) indicate the output load segment the digital current display is reporting
  • Switches: SELECT switch advances the digital display and LED to report power consumption for load segments L1, L2 and L3 (short press); SELECT switch also rotates the local display 90 degrees for overhead power input (long press); SCROLL IP button scrolls the configured IP address (long press)
  • Shipping Dimensions (hwd / in.): 6.6 x 9.3 x 75.5
  • Shipping Weight (lbs.): 17
  • Unit Dimensions (hwd / in.): 70 x 2.19 x 1.67
  • Unit Weight (lbs.): 8.5
  • Material of Construction: Metal
  • Form Factors Supported: Vertical rackmount installation supported with included mounting brackets; supports tooless mounting in button-mount compatible racks
  • PDU Form Factor: 0U; Vertical
  • Storage Temperature Range: 5 to 122F (-15 to 50C)
  • Relative Humidity: 5 to 95% non-condensing
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • TAA Compliant Option: TAA Compliant Version Available - Order Tripp Lite PDU3VN3L1520TAA
  • Certifications: Tested to UL60950-1 (USA, Canada), NOM (Mexico), Class A (Emissions), ROHS
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932906.pdf","title":"Owner's Manual for High Voltage 3-Phase PDU 932906 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/PDU3VN3L1520-PDU3VN10L1520-Submittal-Drawing-EN.pdf","title":"Submittal Drawings"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-monitored-pdus\/75342","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-monitored-pdus\/75342"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4703","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/5.7kw-3-phase-monitored-pdu-208v-outlets-30-c13-6-c19-l15-20p-3ft-cord-0u-vertical~PDU3VN3L1520/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite 3 phase Monitored PDU \/ Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...