SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed Network Management Card, USB, DB9 Serial
Specifications
Additional Information
- UPC: 37332190734
- Manufacturer: TRIPPLITE
- Specifications
- Output Volt Amp Capacity (VA): 750
- Output Watt Capacity (Watts): 600
- Power Factor: 0.8
- Nominal Output Voltage(s) Supported: 110V; 115V; 120V
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 60 Hz
- Output Voltage Regulation (Line Mode): -21%, +8%
- Output Voltage Regulation (Battery Mode): +/- 5%
- Output Receptacles: (6) 5-15R
- Load Management Receptacles: Two switchable single-outlet 5-15R load banks
- Output AC Waveform (AC Mode): Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Rated input current (Maximum Load): 7A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type: 5-15P
- Input Circuit Breakers: 15A
- Recommended Electrical Service: 15A 120V
- Input Cord Length (ft.): 10
- Input Phase: Single-Phase
- Full Load Runtime (min.): 4.9 min. (600w)
- Half Load Runtime (min.): 13.2 min. (300w)
- DC System Voltage (VDC): 24
- Battery Recharge Rate (Included Batteries): Less than 4 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge: RBC64-1U
- Battery Access: Front panel battery access door
- Battery Replacement Description: Hot-swappable, user replaceable batteries
- Expandable Runtime: No
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
- Overvoltage Correction: Input voltages between 128 and 147 are reduced by 12%
- Undervoltage Correction: Input voltages between 83 and 107 are boosted by 14%
- Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation
- Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
- Audible Alarm: Audible alarm indicates power-failure, overload and low-battery conditions
- LED Indicators: 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
- UPS AC Suppression Joule Rating: 450 joules
- UPS AC Suppression Response Time: Instantaneous
- EMI / RFI AC Noise Suppression: Yes
- Included Mounting Accessory Description: Included mounting brackets support 2 and 4 post rackmount installation; Optional 4POSTRAILKIT1U is available for additional support in 4 post rackmount applications
- Primary Form Factor: Rackmount
- UPS Power Module Dimensions (hwd, in.): 1.75 x 17.5 x 16.75
- Rack Height (U Spaces): 1
- Minimum Required Rack Depth (inches): 19.8
- UPS Power Module Weight (lbs.): 30
- UPS Power Module Weight (kg): 13.61
- UPS Shipping Dimensions (hwd / in.): 6.2 x 23.5 x 22.5
- Shipping Weight (lbs.): 34
- Cooling Method: Fan
- UPS Housing Material: Steel
- Minimum Required Rack Depth (mm): 503
- Primary UPS Height (mm): 44
- Primary UPS Width (mm): 444
- Primary UPS Depth (mm): 425
- Shipping Height (mm): 157
- Shipping Width (mm): 597
- Shipping Depth (mm): 572
- Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load): 38
- Battery Mode BTU / Hr. (Full Load): 545
- AC Mode Efficiency Rating (100% Load): 98%
- Communications Interface: DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB
- Network Monitoring Port Description: Includes pre-installed Network Management Card
- PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable: USB and DB9 cabling included
- WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Transfer Time: 5 milliseconds AC to DC; 1 millisecond DC to AC
- Low Voltage Transfer to Battery Power (Setpoint): 83
- High Voltage Transfer to Battery Power (Setpoint): 147
- Grounding Lug: Back panel grounding lug
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Hot swappable batteries
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
- Product Warranty Period (Worldwide): 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
- Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance
- Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932406.pdf","title":"Owner's Manual for SmartPro Rackmount UPS 932406"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/933158.pdf","title":"Free 1-Year Warranty Extension with Registration 933158"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SMART750RM1UN-Runtime-Chart-EN.pdf","title":"SMART750RM1UN runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/6547","title":"Download images for this product"}]}
- Manufacturer Product URL: https://www.tripplite.com/smartpro-120v-750va-600w-line-interactive-sine-wave-ups-1u-rackmount-pre-installed-snmpwebcard-usb-db9-serial~SMART750RM1UN/
- Packaging
- Certifications
- Details: "Overview\nTripp Lite SMART750RM1U 750VA \/.75kVA \/ 600 watt line interactive, sine wave UPS system offers complete power protection for critical network applications in a highly efficient 1U total rack\/tower configuration. Simultaneous-use network management interfaces include USB, RS-232 and Pre-installed Network Management Card accessory. Line interactive voltage regulation, network-grade surge suppression and long-lasting sine wave AC output during blackouts make this UPS ideal for advanced networking applications in datacenters, computer rooms and network closets."
- List price: No