OmniSmart 230V 350VA 225W CE/IEC 60601-1 Medical Grade Line-Interactive UPS with Built-In Isolation Transformer
$358.80

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
OMNIX350HG
Sku:
179270
UPC:
37332140432
Overview Tripp Lite's OMNIX350HG offers medical-grade UPS protection with built-in line interactive voltage regulation, intelligent monitoring and unattended shutdown capability. IEC320 plug & outlets, plus built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise. Tested to CE/IEC 60601-1 as medical electrical equipment. 350VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive voltage regulation corrects brownouts as low as 159V back to normal 230V levels, saving battery reserves for use only during complete power failures. Includes, 2 line phone surge suppression and built-in USB communications port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

Specifications

Additional Information

  • UPC: 37332140432
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 350
  • Output Watt Capacity (Watts): 225
  • Nominal Output Voltage(s) Supported: 220V; 230V; 240V
  • Nominal Voltage Details: 230v nominal inverter output voltage
  • Frequency Compatibility: 50 / 60 Hz
  • Frequency Compatibility Details: Automatic frequency selection
  • Output Voltage Regulation (Line Mode): -18%, +8%
  • Output Receptacles: (6) C13
  • Output AC Waveform (Battery Mode): PWM sine wave
  • Rated input current (Maximum Load): 1.8A
  • Nominal Input Voltage(s) Supported: 230V AC
  • UPS Input Connection Type: C14 inlet
  • UPS Input Connection Description: C14 inlet accepts user-supplied AC power cord with grounded country-specific plug
  • UPS Input Cord Length (ft.): 0.50
  • Recommended Electrical Service: 10A 230V
  • Voltage Compatibility (VAC): 230
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 15.5 min. (225w)
  • Half Load Runtime (min.): 37 min. (115w)
  • DC System Voltage (VDC): 12
  • Battery Recharge Rate (Included Batteries): Less than 7.2 hours from 10% to 90%
  • Internal UPS Replacement Battery Cartridge: RBC52(quantity 2)
  • Battery Access: Battery access door allows hot-swap battery replacement without powering connected equipment off
  • Typical Battery Lifespan: 3-6 years, depending on usage
  • Expandable Runtime: No
  • Voltage Regulation Description: Line interactive UPS offers a single boost level of brownout correction to maintain usable, computer grade output
  • Undervoltage Correction: Input voltages between 159 and 199 are boosted by 14%
  • Switches: Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
  • Audible Alarm: Audible alarm indicates power failure conditions, silenceable via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain (assuming full load)
  • LED Indicators: 4 LEDs indicate line power, battery power, overload and battery low/replace status
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Response Time: Instantaneous
  • Dataline Suppression: 2-Line Tel/DSL
  • Installation Form Factors Supported with Included Accessories: Tower
  • Installation Form Factors Supported with Optional Accessories: Wallmount(UPSWM - tower mounting kit)
  • Primary Form Factor: Tower
  • UPS Power Module Dimensions (hwd, in.): 10.6 x 5.2 x 7.4
  • UPS Power Module Weight (lbs.): 25.4
  • UPS Power Module Weight (kg): 11.52
  • UPS Shipping Dimensions (hwd / in.): 14.1 x 10.4 x 8.2
  • Shipping Weight (lbs.): 27.4
  • Cooling Method: Convection
  • UPS Housing Material: PVC
  • Primary UPS Height (mm): 269
  • Primary UPS Width (mm): 132
  • Primary UPS Depth (mm): 188
  • Shipping Height (mm): 358
  • Shipping Width (mm): 264
  • Shipping Depth (mm): 208
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 15.6
  • Battery Mode BTU / Hr. (Full Load): 124.5
  • Communications Interface: USB
  • Transfer Time: 5 milliseconds AC to battery; 8 milliseconds battery to AC
  • Low Voltage Transfer to Battery Power (Setpoint): 159
  • High Voltage Transfer to Battery Power (Setpoint): 266
  • Grounding Lug: Ground Potential Equalization Connector: POAG-S6/20
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • UPS Certifications: CE; Tested to UL60601-1 (medical grade)
  • Certifications: Tested to CE/ IEC 60601-1 (Series AGOM6832), Class B (emissions)
  • Product Warranty Period (International): 2-year limited warranty
  • Product Warranty Period (Mexico): 2-year limited warranty
  • Product Warranty Period (Puerto Rico): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/9333A2.pdf","title":"Owner's Manual for SMX & OMNIX UPS Systems 9333A2 (Multi-Language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/OMNIX350HG-Runtime-Chart-EN.pdf","title":"OMNIX350HG runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Uninterrupted-Power-Source-Brochure-230V.pdf","title":"UPS 230V Brochure 953431 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Healthcare-Power-Solutions-Brochure-1209047-EN.pdf","title":"Global UPS Systems for Healthcare Brochure (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Healthcare-Medical-Solutions-Brochure-EN.pdf","title":"Healthcare\/Medical Solutions Brochure 953476 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-230v-Brochure-Chinese.pdf","title":"UPS Systems 230V Brochure (Chinese)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4027","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/omnismart-230v-350va-225w-ce-iec-60601-1-medical-grade-line-interactive-ups-built-in-isolation-transformer~OMNIX350HG/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite's OMNIX350HG offers medical-grade UPS protection with built-in line interactive voltage regulation, intelligent monitoring and unattended shutdown capability. IEC320 plug & outlets, plus built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise. Tested to CE\/IEC 60601-1 as medical electrical equipment. 350VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive voltage regulation corrects brownouts as low as 159V back to normal 230V levels, saving battery reserves for use only during complete power failures. Includes, 2 line phone surge suppression and built-in USB communications port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...