Overview Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.

Specifications

Additional Information

  • UPC: 37332180964
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Monitored
  • Output Capacity Details: 18.7kW (240V), 17.9kW (230V), 17.1 (220V), 16.2 (208V), 15.6kW (200V) total capacity; 26A max per output phase (L1-L2, L2-L3, L3-L1); 20A max per breakered outlet bank; 12A max per C13 outlet
  • Frequency Compatibility: 50 / 60 Hz
  • Output Receptacles: (36) C13
  • Output Nominal Voltage: 200; 208; 240
  • Overload Protection: 6 20A circuit breakers, 1 per outlet bank
  • PDU Input Voltage: 200; 208; 240
  • Recommended Electrical Service: 60A 208/240V with IEC309 60A Blue (3P+E) outlet
  • Maximum Input Amps: 45
  • PDU Plug Type: IEC-309 60A BLUE (3P+E)
  • Input Cord Length (ft.): 6
  • Input Phase: 3-Phase
  • Reported Load Segments: Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (B1-B6); Outlets are color-coded and labelled for phase and load bank identification; L1-L2 feeds black outlets (B1 & B4); L2-L3 feeds dark-gray outlets (B2 & B5); L3-L1 feeds light-gray outlets (B3 & B6)
  • Front Panel LCD Display: Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature* and Humidity* information (*requires ENIVIROSENSE option); Small digital display provides detail on the measurement the large display is reporting: Input-phase (L#), Load bank (B#), Sensor (S#), Load unbalance (UB), Output power (OP)
  • Front Panel LEDs: Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH); One additional LED for each output load bank (B1-B6) offers information power availablity: GREEN (<80% load), YELLOW (>80% load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip)
  • Switches: Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options; Additional MODE button advances the LEDs to view the next measurement
  • Shipping Dimensions (hwd / in.): 75.9 x 9.7 x 7.1
  • Shipping Weight (lbs.): 25.4
  • Unit Dimensions (hwd / in.): 70 x 2.17 x 2.49
  • Unit Weight (lbs.): 18.7
  • Material of Construction: Metal
  • Form Factors Supported: Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
  • PDU Form Factor: 0U; Vertical
  • Operating Temperature Range: 32 to 122F (0C to 50C)
  • Storage Temperature Range: 5 to 140F (-15C to 60C)
  • Relative Humidity: 5 to 95% non-condensing
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • SNMP Compatibility: Yes, pre-installed SNMPWEBCARD provides remote monitoring via web, telnet, SSH and SNMP management systems
  • Certifications: Tested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/9332F9.pdf","title":"Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/PDU3VN6G60C-Submittal-Drawing-EN.pdf","title":"Submittal Drawings"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/6227","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/18.7kw-3-phase-monitored-pdu-200-208-240v-outlets-36-c13-iec-309-60a-blue-6-ft-cord-0u-vertical-taa~PDU3VN6G60C/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite 3 phase Monitored PDU \/ Power Distribution Unit offers real-time remote monitoring of voltage and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...