8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (48 C13 & 6 C19), 0U Rack-Mount, Accessory for Select ATS PDUs
Specifications
Additional Information
- UPC: 37332190086
- Manufacturer: TRIPPLITE
- Specifications
- Accessories Type: 0U Strip for 3-Phase ATS PDU
- Output Capacity Details: Supports up to 12.6kW total output; 20A max per output phase (L1-L2, L2-L3, L3-L1) when used with 35A max 208V input ATS models (such as PDU350AT6H50); Supports up to 8.6kW total output; 13.9A max per output phase (L1-L2, L2-L3, L3-L1) when used with 24A max 208V input ATS models (such as PDU330AT6L2130, PDU330AT6L1530 and PDU330AT6L15); All configurations: 16A max per C19 outlet, 12A max per C13 outlet
- Frequency Compatibility: 50 / 60 Hz
- Output Receptacles: (48) C13; (6) C19
- Output Nominal Voltage: 200; 208; 220; 230; 240
- Overload Protection: n/a
- PDU Input Voltage: 200; 208; 220; 230; 240
- Maximum Input Amps: 35
- Input Cord Details: Includes 7 conductor input plug for use with compatible Tripp Lite ATS PDU products only
- Input Cord Length (ft.): 2.5
- Input Phase: 3-Phase
- Shipping Dimensions (hwd / in.): 76.57 x 6.89 x 5.91
- Shipping Weight (lbs.): 14.46
- Unit Dimensions (hwd / in.): 70 x 2.2 x 2.22
- Unit Weight (lbs.): 9.26
- Material of Construction: Metal
- Form Factors Supported: Vertical rackmount installation supported with toolless mounting in button-mount compatible racks
- PDU Form Factor: 0U; Vertical
- Operating Temperature Range: 0 to 50C (32 to 122F)
- Storage Temperature Range: -15C to 60C (5 to 140F)
- Relative Humidity: 5-95% non-condensing
- Operating Elevation (ft.): 0-10,000
- Operating Elevation (msnm): 0-3000
- Certifications: Tested to UL60950-1 (USA), CSA (Canada), NOM (Mexico), FCC Class A (Emissions), ROHS
- Product Warranty Period (Worldwide): 2-year limited warranty
- Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/933363.pdf","title":"Owner's Manual for 3-Phase 1U Monitored Rack PDU with Automatic Transfer Switch (ATS) 933363 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/PDU3V20D354B-Submittal-Drawing-EN.pdf","title":"Submittal Drawings"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Flyer\/3-Phase-Rack-ATS-Product-Announcement-Flyer-953469-EN.PDF","title":"3-Phase Rack ATS PDU Product Announcement Flyer 953469 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/6732","title":"Download images for this product"}]}
- Manufacturer Product URL: https://www.tripplite.com/8.6-12.6kw-3-phase-vertical-pdu-strip-208v-outlets-48-c13-6-c19-0u-rack-mount-accessory-ats-pdus~PDU3V20D354B/
- Packaging
- Certifications
- Details: "Overview\nThe PDU3V20D354B 8.6\/12.6kW 3-Phase Vertical Power Distribution Unit (PDU) Outlet Strip is a required accessory option for Tripp Lites PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other 3-phase auto-transfer switch (ATS) PDUs that specify compatibility with this model. Its ideal for high-density equipment racks in data centers and server rooms.\n\nWhen used with 208V ATS models with a 35A input rating (such as PDU350AT6H50), the PDU3V20D354B supports up to 12.6kW total output with 20A maximum full balanced load per phase combination output bank (L1-L2, L2-L3, L3-L1). When used with 208V ATS PDU models with a 24A input rating (such as PDU330AT6L2130, PDU330AT6L1530 or PDU330AT6L15), it supports up to 8.6kW total output with 13.9A maximum balanced load per phase combination output bank.\n\nThe 48 C13 and 6 C19 single-phase outlets receive power from the the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations (L1-L2, L2-L3, L3-L1) throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers each. The 2.5-foot power cord with 8-position plug connects directly to the PDUs rear receptacle.\n\nThe PDU3V20D354Bs rugged all-metal housing mounts in compatible racks in seconds with no tools needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack."
- List price: No