Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

2.9kW Single-Phase ATS / Metered PDU, 120V Outlets (24 5-15/20R, 1 L5-30R), 2 L5-30P, 2 10ft Cords, 2U Rack-Mount, TAA
$589.99

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PDUMH30AT
Sku:
90644
UPC:
37332157287
Overview Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

Specifications

Additional Information

  • UPC: 37332157287
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Auto-Transfer Switch; Metered
  • Output Capacity Details: 3.05kW (127V), 2.88kW (120V), 2.4kW (100V) / 30A total capacity (Agency de-rated 24A); 24A max per L5-30R outlet; 20A max per breakered load bank; 16A max per 5-15/20R outlet
  • Frequency Compatibility: 60 Hz
  • Output Receptacles: (24) 5-15/20R; (1) L5-30R
  • Output Nominal Voltage: 100; 120; 127
  • Overload Protection: 2 20A output breakers protect 12 5-15/20R outlets each
  • PDU Input Voltage: 100; 120; 127
  • Recommended Electrical Service: 30A 120V
  • Maximum Input Amps: 30
  • Maximum Input Amps Details: Agency de-rated to 24A continuous
  • PDU Plug Type: (2) NEMA L5-30P
  • Input Cord Details: Set of two inputs connect to separate PRIMARY and SECONDARY power sources
  • Input Cord Length (ft.): 10
  • Input Phase: Single-Phase
  • Front Panel LCD Display: Digital display reports output amps in 4 separately metered loading segments (BANK 1: 5-20R outlets #1-12; BANK 2: 5-20R outlets #13-24; BANK 3: L5-30R outlet #25; BANK 4: Total PDU output), whole-PDU output kW load level and input voltage on primary and secondary input lines
  • Front Panel LEDs: 2 LEDs for power status on Primary and Secondary input connection and three additional LEDs to label the displayed numeric value as Amps, kW or Voltage
  • Switches: ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output and input voltage (primary, secondary)
  • Minimum Required Rack Depth (inches): 16.9
  • Shipping Dimensions (hwd / in.): 8 x 20.5 x 17
  • Shipping Weight (lbs.): 17.6
  • Unit Dimensions (hwd / in.): 3.41 x 17.32 x 11.89
  • Unit Weight (lbs.): 13.71
  • Material of Construction: Metal
  • Form Factors Supported: 2U rackmount
  • PDU Form Factor: 2U; Horizontal
  • Minimum Required Rack Depth (mm): 429
  • Storage Temperature Range: 5 to 122F (-15 to 50C)
  • Relative Humidity: 5-95% non-condensing
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • SNMP Compatibility: n/a
  • TVSS Grounding: Rear grounding lug
  • Certifications: Tested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS Complaint, TAA Compliant
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/93323D.pdf","title":"Owner's Manual for Automatic Transfer Switch PDUs 93-323D (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-metered-pdus\/75341","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-metered-pdus\/75341"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4809","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/automatic-transfer-switch-pdu-metered-120v-30a-25-outlets-2u-single-phase~PDUMH30AT/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite Metered ATS \/ Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability."
  • List price: No