Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

5.8kW Single-Phase 208/240V ATS/Monitored PDU, L6-30R Outlet, 2 L6-30P Inputs, 1U Rack-Mount
$684.99

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PDUMNH30HVAT
Sku:
1485269
UPC:
37332184917
Overview The PDUMNH30HVAT 5.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-30R outletperfect for connecting a single device or a 0U 208/240V PDU with an L6-30P plug. Dual 10-foot input cords with L6-30P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 15 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).

Specifications

Additional Information

  • UPC: 37332184917
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Monitored; Auto-Transfer Switch
  • Output Capacity Details: 5.8kW (240V), 5.5kW (230V), 5.3kW (220V), 5.0kW (208V), 4.8kW (200V); 30A maximum (agency de-rated to 24A continuous)
  • Frequency Compatibility: 50 / 60 Hz
  • Output Receptacles: (1) L6-30R
  • Output Nominal Voltage: 240, 230, 220, 208, 200
  • PDU Input Voltage: 200; 208; 220; 230; 240
  • Recommended Electrical Service: 30A 208V; 30A 240V
  • Maximum Input Amps: 30
  • Maximum Input Amps Details: Agency de-rated to 24A continuous
  • PDU Plug Type: (2) NEMA L6-30P
  • Input Cord Details: Set of two inputs connect to separate PRIMARY and SECONDARY power sources
  • Input Cord Length (ft.): 10
  • Input Phase: Single-Phase
  • Front Panel LCD Display: Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor
  • Front Panel LEDs: Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status
  • Switches: ENTER and MODE switches toggle the digital display to display all reported information
  • Minimum Required Rack Depth (inches): 17.5
  • Shipping Dimensions (hwd / in.): 7.48 x 21.65 x 20.67
  • Shipping Weight (lbs.): 18.53
  • Unit Dimensions (hwd / in.): 1.72 x 16.93 x 14
  • Unit Weight (lbs.): 15.37
  • Material of Construction: Metal
  • Form Factors Supported: 1U rackmount
  • PDU Form Factor: 1U; Horizontal
  • Minimum Required Rack Depth (mm): 444
  • Operating Temperature Range: 32 to 122F (0-50C)
  • Storage Temperature Range: 5 to 140F (-15 to 60C)
  • Relative Humidity: 5 to 95% (non-condensing)
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • Certifications: Tested to UL/CSA 60950-1 (USA, Canada), FCC Class A (Emissions), NOM (Mexico), RoHS Complaint
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/93338F.pdf","title":"Owner's Manual for PDUMNH16HVAT, PDUMNH20HVAT, PDUMNH30HVAT and PDUMNH32HVAT 93338F (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/PDUMNH30HVAT-Submittal-Drawing-EN.pdf","title":"Submittal Drawings"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/6735","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/5.8kw-single-phase-208-240v-ats-monitored-pdu-l6-30r-outlet-2-l6-30p-inputs-1u-rack-mount~PDUMNH30HVAT/
  • Packaging

  • Certifications

  • Details: "Overview\nThe PDUMNH30HVAT 5.8kW Single-Phase 208\/240V ATS\/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-30R outletperfect for connecting a single device or a 0U 208\/240V PDU with an L6-30P plug.\n\nDual 10-foot input cords with L6-30P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 15 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.\n\nBuilt-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load\/current data with billing-grade accuracy (+\/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A\/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately)."
  • List price: No