Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount, TAA
$444.99

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PDUMH15ATNET
Sku:
11571
UPC:
0037332136428
Overview Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

Specifications

Additional Information

  • UPC: 0037332136428
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Auto-Transfer Switch; Switched
  • Output Capacity Details: 1.52kW (127V), 1.44kW (120V), 1.2kW (100V) / 15A total capacity (Agency de-rated to 12A); 12A max per outlet
  • Frequency Compatibility: 60 Hz
  • Output Receptacles: (8) 5-15R
  • Output Nominal Voltage: 100; 120; 127
  • Overload Protection: n/a
  • Customized Load Management Receptacles: 8 individually switched output receptacles
  • PDU Input Voltage: 100; 120; 127
  • Recommended Electrical Service: 15A 120V
  • Maximum Input Amps: 15
  • Maximum Input Amps Details: Agency de-rated to 12A continuous
  • PDU Plug Type: (2) NEMA 5-15P
  • Input Cord Details: Set of 2 inputs enable connection to separate PRIMARY and SECONDARY power sources
  • Input Cord Length (ft.): 12
  • Input Phase: Single-Phase
  • Front Panel LCD Display: Digital display reports total PDU output current in amps
  • Front Panel LEDs: 8 LEDs display power on-off status for each output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs
  • Switches: n/a
  • Minimum Required Rack Depth (inches): 17.5
  • Shipping Dimensions (hwd / in.): 5.2 x 20.8 x 23.2
  • Shipping Weight (lbs.): 16
  • Unit Dimensions (hwd / in.): 1.75 x 17.5 x 14.5
  • Unit Weight (lbs.): 11
  • Material of Construction: Metal
  • Form Factors Supported: 1U rackmount
  • PDU Form Factor: 1U; Horizontal
  • Minimum Required Rack Depth (mm): 444
  • Storage Temperature Range: 5 to 122F (-15 to 50C)
  • Relative Humidity: 5-95% non-condensing
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • SNMP Compatibility: Yes, pre-installed SNMPWEBCARD provides remote monitoring via network interface
  • TVSS Grounding: Rear grounding lug
  • Certifications: Tested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932857.pdf","title":"Owner's Manual for PDUMH15-20AT\/PDUMH15-20ATNET PDU 932857"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932607.pdf","title":"Quick Start Guide for SNMPWEBCARD 932607"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other\/case-study\/Tripp-Lite-Protects-Cisco-Digital-Media-System-Case-Study-EN.pdf","title":"Tripp Lite Protects Cisco Digital Media System Case Study - Cisco Digital Media System Protection (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/case-study\/csid\/loma-linda-ups-for-hospitals","title":"Loma Linda UPS for Hospitals"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/3495","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/1.4kw-single-phase-ats-switched-pdu-120v-8-5-15r-2-5-15p-100-127v-input-2-12ft-cords-1u-rack-mount~PDUMH15ATNET/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite Switched ATS \/ Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...