3.2-3.8kW Single-Phase ATS/Switched PDU, 200-240V Outlets (8 C13 & 2 C19), 2 C20, 12ft Cord, 1U Rack-Mount, TAA
$659.99

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PDUMH20HVATNET
Sku:
90608
UPC:
37332151506
Overview Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

Specifications

Additional Information

  • UPC: 37332151506
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Auto-Transfer Switch; Switched
  • Output Capacity Details: 3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet
  • Frequency Compatibility: 50 / 60 Hz
  • Output Receptacles: (8) C13; (2) C19
  • Output Nominal Voltage: 200; 208; 220; 230; 240
  • Overload Protection: n/a
  • Customized Load Management Receptacles: 8 individually switched C13 output receptacles
  • PDU Input Voltage: 200; 208; 220; 230; 240
  • Recommended Electrical Service: 20A 208/240V; 16A 230V
  • Maximum Input Amps: 20
  • Maximum Input Amps Details: Agency de-rated to 16A continuous
  • PDU Plug Type: (2) IEC-320 C20
  • Input Cord Details: Set of two inputs connect to separate PRIMARY and SECONDARY power sources
  • Input Cord Length (ft.): 12
  • Input Phase: Single-Phase
  • Front Panel LCD Display: Digital display reports total PDU output current in amps
  • Front Panel LEDs: 8 LEDs display power on-off status for each C13 output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs
  • Switches: Toggle switch near digital display enables the setting of "HI" for 220, 230 or 240V nominal applications or "LO" for 200 or 208V applications
  • Minimum Required Rack Depth (inches): 18.3
  • Shipping Dimensions (hwd / in.): 5.3 x 23.6 x 21
  • Shipping Weight (lbs.): 19.98
  • Unit Dimensions (hwd / in.): 1.72 x 17.3 x 14.8
  • Unit Weight (lbs.): 10.3
  • Material of Construction: Metal
  • Form Factors Supported: 1U rackmount
  • PDU Form Factor: 1U; Horizontal
  • Minimum Required Rack Depth (mm): 465
  • Storage Temperature Range: 5 to 122F (-15 to 50C)
  • Relative Humidity: 5-95% (non-condensing)
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • SNMP Compatibility: Yes, via pre-installled SNMPWEBCARD. Provides remote monitoring, outlet control, and automatic power management configurations.
  • Certifications: Tested to UL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico), RoHS Complaint, TAA Compliant
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932945.pdf","title":"Owner's Manual for Switched\/Metered Rack PDUs 932945"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/230V-PDU-Specification-Brochure-EN.pdf","title":"230V Power Distribution Unit (PDU) Specification Brochure 9533FF (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4500","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/3.2-3.8kw-single-phase-ats-switched-pdu-200-240v-outlets-8-c13-2-c19-2-c20-12ft-cord-1u-rack-mount-taa~PDUMH20HVATNET/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite Switched ATS \/ Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...