Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartPro 208 & 120V 5kVA 4kW Line-Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9
$2,789.99

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SMART5000RT3U
Sku:
84592
UPC:
37332099242
Overview Tripp Lite's line-interactive SMART5000RT3U UPS System protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower/rackmount housing. In rack configuration, the power module and battery pack occupy only 3 rack spaces (3U) each. Large capacity 5000VA/4000W power module converts raw 208V AC input to fully regulated dual output 208/120 voltage for simultaneous protection of both high- and low-voltage equipment loads. True sine wave output at all times offers guaranteed compatibility with all equipment types. Includes 14 outlets, 8 of which can be individually reset via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended indefinitely with additional external 3U rackmount battery packs. Includes slot for internal Network Management Card option. Also includes two DB9 and two USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data.

Specifications

Additional Information

  • UPC: 37332099242
  • Manufacturer: TRIPPLITE
  • Width: No
  • Height: No
  • Length: No
  • Applications: No
  • Benefits: No
  • Technical: No
  • Warranty: No

  • Specifications
  • Output Volt Amp Capacity (VA): 5000
  • Output kVA Capacity (kVA): 5
  • Output Watt Capacity (Watts): 4000
  • Output kW Capacity (kW): 4
  • Output Capacity Details: Output increases to 4800W maximum when user supplied 50A input plug or hardwire input is used
  • Power Factor: 0.8
  • Nominal Output Voltage(s) Supported: 110V; 115V; 120V; 208V
  • Nominal Voltage Details: 208/120V nominal output in battery mode
  • Frequency Compatibility: 60 Hz
  • Output Voltage Regulation (Line Mode): 208 & 120V (-10%, +20%)
  • Output Voltage Regulation (Battery Mode): +/- 5%
  • Output Receptacles: (10) 5-15R; (2) 5-15/20R; (1) L14-30R; (1) L6-30R
  • Load Management Receptacles: Eight switchable single-outlet 5-15R load banks
  • Output Circuit Breakers: 15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and L14-30R outlets are unbreakered
  • Output AC Waveform (AC Mode): Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 24A max. in factory L6-30P configuration; 27A max. when powered by 50A plug or hardwire input
  • Nominal Input Voltage(s) Supported: 208V AC
  • UPS Input Connection Type: L6-30P
  • Input Circuit Breakers: 30A double-pole
  • UPS Input Cord Length (ft.): 10
  • Recommended Electrical Service: 30A 208V
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 16 min. (4000w)
  • Half Load Runtime (min.): 38 min. (2000w)
  • Expandable Battery Runtime: Extended runtime supported via optional external battery packs
  • External Battery Pack Compatibility: BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible)
  • DC System Voltage (VDC): 48
  • Battery Recharge Rate (Included Batteries): Less than 4 hours from 10% to 90% (typical, full load discharge)
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282
  • Overvoltage Correction: Input voltages between 240V and 260 are reduced by 12%
  • Undervoltage Correction: Input voltages between 180V and 199 are boosted by 12%
  • Severe Undervoltage Correction: Input voltages between 151V and 179 are boosted by 24%
  • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
  • Audible Alarm: Audible alarm indicates power-failure, overload and low-battery conditions
  • LED Indicators: 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
  • UPS AC Suppression Joule Rating: 1020
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Included Mounting Accessory Description: 2 sets of 4 post rackmount installation accessories for included UPS and battery pack components
  • Installation Form Factors Supported with Included Accessories: 4 post 19 inch rackmount
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
  • Optional Mounting Accessory Notes: 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack; 2-9USTAND tower kit included(supports up to 9U in tower format)
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 5.2 x 17.5 x 22.5
  • Rack Height (U Spaces): 6
  • Minimum Required Rack Depth (inches): 29.5
  • UPS Power Module Weight (lbs.): 93
  • UPS Power Module Weight (kg): 42.18
  • UPS Dimensions Details: Includes 3U UPS/power module and 3U external battery pack
  • Included Battery Pack Dimensions (hwd / in.): 5.2 x 17.5 x 25
  • Included Battery Pack Weight (lbs.): 163
  • UPS Shipping Dimensions (hwd / in.): 24.5 x 24 x 34
  • Shipping Weight (lbs.): 321.6
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 749
  • Primary UPS Height (mm): 132
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 572
  • Shipping Height (mm): 622
  • Shipping Width (mm): 610
  • Shipping Depth (mm): 864
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • Battery Mode BTU / Hr. (Full Load): 1518
  • AC Mode Efficiency Rating (100% Load): 94%
  • Communications Interface: USB; DB9 Serial; Contact closure
  • Network Management Cards: SNMPWEBCARD; WEBCARDLX
  • Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB and DB9 cabling included
  • WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
  • Transfer Time: 2-4 milliseconds
  • Low Voltage Transfer to Battery Power (Setpoint): 151
  • High Voltage Transfer to Battery Power (Setpoint): 260
  • Grounding Lug: Back panel grounding lug
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Hot swappable batteries
  • UPS Certifications: Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
  • Product Warranty Period (Worldwide): 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932159.pdf","title":"Owner's Manual for SMART5000RT3U SmartPro UPS 932159"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/933158.pdf","title":"Free 1-Year Warranty Extension with Registration 933158"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SMART5000RT3U-Runtime-Chart-EN.pdf","title":"SMART5000RT3U runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/60","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartpro-208-120v-5kva-4kw-line-interactive-sine-wave-ups-6u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial~SMART5000RT3U/
  • Packaging

  • Certifications

  • Key Features: No
  • Details: "Overview\nTripp Lite's line-interactive SMART5000RT3U UPS System protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower\/rackmount housing. In rack configuration, the power module and battery pack occupy only 3 rack spaces (3U) each. Large capacity 5000VA\/4000W power module converts raw 208V AC input to fully regulated dual output 208\/120 voltage for simultaneous protection of both high- and low-voltage equipment loads. True sine wave output at all times offers guaranteed compatibility with all equipment types. Includes 14 outlets, 8 of which can be individually reset via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended indefinitely with additional external 3U rackmount battery packs. Includes slot for internal Network Management Card option. Also includes two DB9 and two USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data."
  • List price: No
  • Weight: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 