Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartOnline 208/240 & 120V 6kVA 4.2kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch
$3,502.78

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU6000RT4U
Sku:
12682
UPC:
0037332125217
Overview Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4U provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems. The SU6000RT4U has a 6kVA/4200W capacity, NEMA L14-30P 4-wire split-phase input and 12 total AC outlets (8 5-15/20R; 2 L6-20R; 2 L6-30R). With its detachable PDU, the SU6000RT4U is easily hot-swappable by a user of any skill setno need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4Us runtime can be expanded with optional external battery packs. The SU6000RT4U features a highly efficient (94%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity. An LCD display with LED indicators enables IT personnel to monitor operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions. The SU6000RT4U features a USB port and a DB9 port that, when used with Tripp Lite's PowerAlert software, provides comprehensive network power monitoring and control. An optional network accessory card enables the UPS to operate as a network managed device. The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory. The SU6000RT4U comes with$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment.

Specifications

Additional Information

  • UPC: 0037332125217
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 6000
  • Output kVA Capacity (kVA): 6
  • Output Watt Capacity (Watts): 4200
  • Output kW Capacity (kW): 4.2
  • Output Capacity Details: 6,000VA / 4200W (240V) / 5400VA / 4200W (208V); Supports up to 105% load continuously in double conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared
  • Power Factor: 0.7
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 120V; 208V; 240V
  • Nominal Voltage Details: 240/120 or 208/120 split phase output
  • Frequency Compatibility: 60 Hz
  • Output Voltage Regulation (Line Mode): +/- 3%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 3%
  • Output Receptacles: (8) 5-15/20R; (2) L6-20R; (2) L6-30R
  • Output Circuit Breakers: 20A branch rated breakers (x4) protect 2 5-15/20R outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R outlets are unbreakered
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 24A
  • Nominal Input Voltage(s) Supported: 120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G)
  • UPS Input Connection Type: L14-30P
  • UPS Input Connection Description: 4 wire split-phase input (L1, L2, N, G)
  • UPS Input Cord Length (ft.): 10
  • Recommended Electrical Service: 30A 208/120V Split Phase
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 8 min. (4200w)
  • Half Load Runtime (min.): 20 min. (2100w)
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
  • External Battery Pack Compatibility: BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; BP192V5RT2U(limit 1)
  • DC System Voltage (VDC): 192
  • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 80% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: RBC9-192
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: +/-3% output voltage regulation in online, double-conversion mode
  • Overvoltage Correction: Corrects overvoltages to 140 (measured L1-N : L2-N)
  • Undervoltage Correction: Corrects undervoltages to 65 (measured L1-N : L2-N)
  • Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats
  • Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads. Battery Charge level switch allows the charger output to be adjusted to a higher charge rate when external battery packs are added.
  • Alarm Cancel Operation: Alarm cancel switch
  • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
  • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Response Time: Instantaneous
  • Included Mounting Accessory Description: 4 post rackmount installation accessories included
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 7 x 17.5 x 30.8
  • Rack Height (U Spaces): 4
  • Maximum Device Depth (in.): 30.8
  • Minimum Required Rack Depth (inches): 35.8
  • UPS Power Module Weight (lbs.): 149.6
  • UPS Power Module Weight (kg): 67.86
  • UPS Dimensions Details: Includes 4U UPS/power module plus SUPDMB56 detachable PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
  • UPS Shipping Dimensions (hwd / in.): 13.2 x 37 x 23
  • Shipping Weight (lbs.): 189.2
  • Cooling Method: Fan
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 909
  • Primary UPS Height (mm): 178
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 782
  • Shipping Height (mm): 335
  • Shipping Width (mm): 940
  • Shipping Depth (mm): 584
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 1593
  • AC Economy Mode BTU / Hr. (Full Load): 914
  • Battery Mode BTU / Hr. (Full Load): 1419
  • AC Economy Mode Efficiency Rating (100% Load): 94%
  • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
  • Audible Noise: 60 dBA at front side 1 meter
  • Operating Elevation (msnm): 0-3000 m
  • Communications Interface: USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: RS232 and contact closure communications are supported on one DB9 port
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB and DB9 cabling included
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Low Voltage Transfer to Battery Power (Setpoint): 65V (L1-N:L2-N)
  • High Voltage Transfer to Battery Power (Setpoint): 140V (L1-N:L2-N)
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
  • Green Energy-Saving Features: High efficiency economy mode operation; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932611.pdf","title":"Owner's Manual for SU5000RT4U\/SU6000RT4U\/SU8000RT4U UPS 932611"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU6000RT4U-Runtime-Chart-EN.pdf","title":"SU6000RT4U runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other\/case-study\/AMD-Case-Study-EN.pdf","title":"AMD Case Study - Automated Test Stress Lab Protection (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/su6000rt4u-smartonline-ups-system\/60567","title":"https:\/\/www.tripplite.com\/video\/su6000rt4u-smartonline-ups-system\/60567"},{"url":"https:https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731","title":"https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/3184","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240-120v-6kva-4.2kw-double-conversion-ups-4u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial-bypass-switch~SU6000RT4U/
  • Packaging

  • Certifications

  • Details: "Overview\nFeaturing true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4U provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems. The SU6000RT4U has a 6kVA\/4200W capacity, NEMA L14-30P 4-wire split-phase input and 12 total AC outlets (8 5-15\/20R; 2 L6-20R; 2 L6-30R).\n\nWith its detachable PDU, the SU6000RT4U is easily hot-swappable by a user of any skill setno need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation.\n\nUPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4Us runtime can be expanded with optional external battery packs.\n\nThe SU6000RT4U features a highly efficient (94%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.\n\nAn LCD display with LED indicators enables IT personnel to monitor operating modes and conditions. The LCD\/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.\n\nThe SU6000RT4U features a USB port and a DB9 port that, when used with Tripp Lite's PowerAlert software, provides comprehensive network power monitoring and control. An optional network accessory card enables the UPS to operate as a network managed device.\n\nThe unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory.\n\nThe SU6000RT4U comes with$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...