SmartOnline 200-240V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire
$5,975.01

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU12KRT4UHW
Sku:
156009
UPC:
37332157119
Overview Tripp Lite SU12KRT4UHW 12,000VA / 12Kva / 10,800 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in an 8U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 6kVA, and non-redundant operation at loads between 6 and 12kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

Specifications

Additional Information

  • UPC: 37332157119
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 12000
  • Output kVA Capacity (kVA): 12
  • Output Watt Capacity (Watts): 10800
  • Output kW Capacity (kW): 10.8
  • Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
  • Power Factor: 0.9
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 200V; 208V; 220V; 230V; 240V
  • Nominal Voltage Details: Voltage selection via front panel LCD interface
  • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
  • Frequency Compatibility Details: Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: Hardwire
  • Output Receptacle Details: Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 63.8A (200V), 61.2A (208V), 58A (220V), 55.4A (230V), 53.2A (240V)
  • Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
  • UPS Input Connection Type: Hardwire
  • UPS Input Connection Description: Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
  • Recommended Electrical Service: 70A
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 2 minutes (10,800 watts)
  • Half Load Runtime (min.): 8.5 minutes (5400 watts)
  • Expandable Battery Runtime: Runtime is expandable with external battery packs
  • External Battery Pack Compatibility: BP192V12-3U; BP192V557C-1PH; BP192V787C-1PH; BP192V1037C-1PH; BP192V1407C-1PH
  • Expandable Runtime Description: For best results, add external batteries in multiples of two so that both included 6kVA power modules have an equal number and type of connected battery packs
  • DC System Voltage (VDC): 192
  • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 90% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: Each of the two included 6kVA power modules contain one RBC5-192 internal replacement battery cartridge
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable internal battery cartridges and external battery packs
  • Expandable Runtime: Yes
  • Voltage Regulation Description: +/-2% output voltage regulation in standard online, double-conversion mode
  • Overvoltage Correction: Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
  • Undervoltage Correction: Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
  • Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
  • Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
  • Alarm Cancel Operation: Alarm cancel switch
  • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
  • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Included Mounting Accessory Description: Includes 4 post mounting accessories for each included component
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
  • Optional Mounting Accessory Notes: Qty 2 2POSTRMKITHD required for 2 post rackmount installation of all included components
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 6.85 x 17.5 x 20.7
  • Rack Height (U Spaces): 8
  • Maximum Device Depth (in.): 24
  • Minimum Required Rack Depth (inches): 35.2
  • UPS Power Module Weight (lbs.): 108
  • UPS Power Module Weight (kg): 48.99
  • UPS Dimensions Details: Includes two 4U UPS/power modules plus SUPDMB12HW detachable parallel bypass PDU; UPS Power Module Dimensions are for one of the two included UPS/power modules; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
  • UPS Shipping Dimensions (hwd / in.): 41 x 24 x 34
  • Shipping Weight (lbs.): 342
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 894
  • Primary UPS Height (mm): 174
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 526
  • Shipping Height (mm): 1041
  • Shipping Width (mm): 610
  • Shipping Depth (mm): 864
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 3534
  • AC Economy Mode BTU / Hr. (Full Load): 1535
  • Battery Mode BTU / Hr. (Full Load): 4558
  • AC Mode Efficiency Rating (100% Load): 90%
  • AC Economy Mode Efficiency Rating (100% Load): 96%
  • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
  • Audible Noise: 60 dBA at front side 1 meter
  • Operating Elevation (msnm): 0-3000 m
  • Communications Interface: USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: Applications utilizing any supported network management card option, require the use of two network cards of the same-model (install one card per included UPS power module); RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB, DB9 serial and EPO cables included
  • WatchDog Compatibility: Yes
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Transfer Time (Economy Mode): 8 milliseconds typical in optional economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): 156V (full load) / 100V (50% load or less, derates linearly)
  • High Voltage Transfer to Battery Power (Setpoint): 280V (full load) / 300V (90% load or less)
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
  • Green Energy-Saving Features: High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
  • UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240-230v-12kva-10.8kw-double-conversion-ups-n-1-8u-rack-tower-extended-run-snmpwebcard-option-usb-db9-bypass-switch-hardwire~SU12KRT4UHW/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite SU12KRT4UHW 12,000VA \/ 12Kva \/ 10,800 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in an 8U rack\/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 6kVA, and non-redundant operation at loads between 6 and 12kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...