Overview Tripp Lite SU16KRTG 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

Specifications

Additional Information

  • UPC: 37332158246
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 16000
  • Output kVA Capacity (kVA): 16
  • Output Watt Capacity (Watts): 14400
  • Output kW Capacity (kW): 14.4
  • Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
  • Power Factor: 0.9
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 200V; 208V; 220V; 230V; 240V
  • Nominal Voltage Details: Voltage selection via front panel LCD interface
  • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
  • Frequency Compatibility Details: Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: (8) C19
  • Output Circuit Breakers: 8 20A breakers protect one C19 outlet each
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 92A (200V), 88.4A (208V), 83.6A (220V), 80A (230V), 76.6A (240V)
  • Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
  • UPS Input Connection Type: Hardwire
  • UPS Input Connection Description: Hardwire input supports North American 208/240V input (L1, L2, G) and International 230/220/240V input (L, N, PE)
  • Recommended Electrical Service: 100A @ 200V-240V (L, N, PE), or 100A @ 200V, 208V, or 240V (L1, L2, G)
  • Voltage Compatibility (VAC): 200; 208; 230; 240; 220
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 5.5 minutes (14,400 watts)
  • Half Load Runtime (min.): 13.5 minutes (7200 watts)
  • Expandable Battery Runtime: Runtime is expandable with external battery packs
  • External Battery Pack Compatibility: BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH
  • Expandable Runtime Description: For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs
  • DC System Voltage (VDC): 240
  • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 90% (typical, full load discharge)
  • Battery Replacement Description: Hot-swappable, user replaceable external battery packs
  • Expandable Runtime: Yes
  • Voltage Regulation Description: 2% output voltage regulation in standard online, double-conversion mode
  • Overvoltage Correction: Corrects overvoltages up to 300V
  • Undervoltage Correction: Corrects undervoltages as low as 100V
  • Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
  • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
  • Alarm Cancel Operation: Alarm cancel switch
  • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
  • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Included Mounting Accessory Description: 4 sets of adjustable 4 post rack rails included (one for each included 3U module)
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
  • Optional Mounting Accessory Notes: Qty 4 2POSTRMKITHD required; Qty 2 2-9USTAND required
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 5.14 x 17.5 x 25.82
  • Rack Height (U Spaces): 12
  • Maximum Device Depth (in.): 32.5
  • Minimum Required Rack Depth (inches): 37.5
  • UPS Power Module Weight (lbs.): 43
  • UPS Power Module Weight (kg): 19.50
  • UPS Dimensions Details: Includes 2 SU8000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs and SUPDMB20KIEC parallel bypass PDU; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed
  • Included Battery Pack Dimensions (hwd / in.): 5.25 x 17.5 x 25
  • Included Battery Pack Weight (lbs.): 158.7
  • UPS Shipping Dimensions (hwd / in.): 36 x 40.25 x 51
  • Shipping Weight (lbs.): 600
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 952
  • Primary UPS Height (mm): 131
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 656
  • Shipping Height (mm): 914
  • Shipping Width (mm): 1022
  • Shipping Depth (mm): 1295
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 5464
  • AC Economy Mode BTU / Hr. (Full Load): 2047
  • Battery Mode BTU / Hr. (Full Load): 4864
  • AC Mode Efficiency Rating (100% Load): 90%
  • AC Economy Mode Efficiency Rating (100% Load): 96%
  • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
  • Audible Noise: 60 dBA at front side 1 meter
  • Operating Elevation (msnm): 0-3000 m
  • Communications Interface: USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: Applications utilizing any supported network management card option, require the use of two network cards of the same-model (install one card per included UPS power module); RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB, DB9 serial and EPO cables included
  • WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Transfer Time (Economy Mode): 8 milliseconds typical power failure response in optional economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): 100V
  • High Voltage Transfer to Battery Power (Setpoint): 300V
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • Economy Mode Operation: Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
  • Green Energy-Saving Features: High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); CE; Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
  • UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932897.pdf","title":"Owner's Manual for SmartOnline 8kVA-10kVA UPS 932897 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/933240.pdf","title":"Owner's Manual for 8 and 10kVA Parallel PDUs 933240 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU16KRTG-Runtime-Chart-EN.pdf","title":"SU16KRTG runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Uninterrupted-Power-Source-Brochure-230V.pdf","title":"UPS 230V Brochure 953431 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/95-33C1-SmartOnline-Hot-Swap-UPS-Brochure-230V.pdf","title":"SmartOnline Hot-Swap 230V UPS Brochure 9533C1 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-230v-Brochure-Chinese.pdf","title":"UPS Systems 230V Brochure (Chinese)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932487.PDF","title":"Owner's Manual for BP Battery 932487 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/16kva-smartonline-ups-hot-swap-demo\/45727","title":"https:\/\/www.tripplite.com\/video\/16kva-smartonline-ups-hot-swap-demo\/45727"},{"url":"https:https:\/\/www.tripplite.com\/video\/su16krtg-smartonline-ups-system\/60553","title":"https:\/\/www.tripplite.com\/video\/su16krtg-smartonline-ups-system\/60553"},{"url":"https:https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731","title":"https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4677","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240-230v-16kva-14.4kw-double-conversion-ups-n-1-12u-rack-tower-extended-run-snmpwebcard-option-usb-db9-bypass-switch-c19~SU16KRTG/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite SU16KRTG 16,000VA \/ 16kVA \/ 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack\/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...