Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartOnline 208/240, 230V 6kVA 5.4kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, C19
$2,952.79

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU6000RT4UHVG
Sku:
91779
UPC:
0037332157232
Overview Tripp Lite SU6000RT4UHVG 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack/tower compatible housing. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports hot-swappable whole UPS replacement with no interruption to connected equipment. Single all-in-one rack / tower housing installs in only 4 rack spaces (4U) with a maximum installed depth of only 20.7 in. / 52.6cm. Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional network management card options available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire input and 4 C19 outlets. Support for optional North American and International cordsets. External battery packs are field replaceable and hot swappable.

Specifications

Additional Information

  • UPC: 0037332157232
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 6000
  • Output kVA Capacity (kVA): 6.0
  • Output Watt Capacity (Watts): 5400
  • Output kW Capacity (kW): 5.4
  • Output Capacity Details: Output capacity de-rates to 4992 watts when used at 208V with optional L6-30P line cord; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared
  • Power Factor: 0.9
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 200V; 208V; 220V; 230V; 240V
  • Nominal Voltage Details: Voltage selection via front panel LCD interface
  • Frequency Compatibility: 50 / 60 Hz
  • Frequency Compatibility Details: Output frequency matches input nominal on startup; Frequency conversion mode enable conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: (4) C19
  • Output Receptacle Details: Output receptacle and input connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
  • Output Circuit Breakers: Two 20A breakers protect 2 C19 outlets each
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
  • Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
  • Nominal Input Voltage Description: Factory configured to 208V
  • UPS Input Connection Type: Hardwire
  • UPS Input Connection Description: Supports North American 208/240V input (L1,L2,G) or International 230/220/240V (L,N,PE) input wiring; Optional SU30ACORD offers NEMA L6-30P input
  • Recommended Electrical Service: 40A (200/208v); 30-32A (220/230/240v)
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 2 minutes (5400 watts)
  • Half Load Runtime (min.): 8.5 minutes (2700 watts)
  • Expandable Battery Runtime: Runtime is expandable with external battery packs
  • External Battery Pack Compatibility: BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH
  • DC System Voltage (VDC): 192
  • Battery Recharge Rate (Included Batteries): 6 hours from 10% to 90% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: RBC5-192
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable internal batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
  • Undervoltage Correction: Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
  • Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats
  • Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.
  • Alarm Cancel Operation: Alarm cancel switch
  • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
  • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
  • UPS AC Suppression Response Time: Instantaneous
  • Included Mounting Accessory Description: Includes 4 post rackmount installation accessories
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 6.85 x 17.5 x 20.67
  • Rack Height (U Spaces): 4
  • Maximum Device Depth (in.): 20.7
  • Minimum Required Rack Depth (inches): 28.7
  • UPS Power Module Weight (lbs.): 108
  • UPS Power Module Weight (kg): 48.99
  • UPS Shipping Dimensions (hwd / in.): 12.7 x 23.6 x 29.1
  • Shipping Weight (lbs.): 156.5
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 729
  • Primary UPS Height (mm): 174
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 525
  • Shipping Height (mm): 323
  • Shipping Width (mm): 599
  • Shipping Depth (mm): 739
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 1767
  • AC Economy Mode BTU / Hr. (Full Load): 768
  • Battery Mode BTU / Hr. (Full Load): 2279
  • AC Mode Efficiency Rating (100% Load): 90%
  • AC Economy Mode Efficiency Rating (100% Load): 96%
  • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
  • Audible Noise: 60 dBA at front side 1 meter
  • Operating Elevation (msnm): 0-3000 m
  • Communications Interface: USB
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB, DB9 serial and EPO cables included
  • WatchDog Compatibility: Yes
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Transfer Time (Economy Mode): 8 ms. typical power failure response in optional economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): 156V (full load) / 100V (50% load or less, derates linearly)
  • High Voltage Transfer to Battery Power (Setpoint): 280V (full load) / 300V (90% load or less)
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • UPS Certifications: CE; Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to UL1778 (USA)
  • UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240-230v-6kva-5.4kw-double-conversion-ups-4u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial-bypass-switch-c19~SU6000RT4UHVG/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite SU6000RT4UHVG 6000VA \/ 6kVA \/ 5400 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack\/tower compatible housing. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports hot-swappable whole UPS replacement with no interruption to connected equipment. Single all-in-one rack \/ tower housing installs in only 4 rack spaces (4U) with a maximum installed depth of only 20.7 in. \/ 52.6cm. Maintains full-time sine wave output within 2% of selectable 200\/208\/220\/230\/240V nominal during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional network management card options available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED \/ LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire input and 4 C19 outlets. Support for optional North American and International cordsets. External battery packs are field replaceable and hot swappable."