SmartOnline 208/240, 230V 6kVA 5.4kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, Hardwire
Specifications
Additional Information
- UPC: 37332157089
- Manufacturer: TRIPPLITE
- Specifications
- Output Volt Amp Capacity (VA): 6000
- Output kVA Capacity (kVA): 6.0
- Output Watt Capacity (Watts): 5400
- Output kW Capacity (kW): 5.4
- Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared
- Power Factor: 0.9
- Crest Factor: 3:1
- Nominal Output Voltage(s) Supported: 200V; 208V; 220V; 230V; 240V
- Nominal Voltage Details: Voltage selection via front panel LCD interface
- Frequency Compatibility: 50 / 60 Hz
- Frequency Compatibility Details: Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
- Output Voltage Regulation (Line Mode): +/- 2%
- Output Voltage Regulation (Economy Line Mode): +/- 10%
- Output Voltage Regulation (Battery Mode): +/- 2%
- Output Receptacles: Hardwire
- Output Receptacle Details: Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
- Output AC Waveform (AC Mode): Pure Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Rated input current (Maximum Load): 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
- Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
- UPS Input Connection Type: Hardwire
- UPS Input Connection Description: Supports North American 208/240V input (L1,L2,G) or International 230/220/240V (L,N,PE) input wiring
- Recommended Electrical Service: 40A (200/208v); 30A (220/230/240v)
- Input Phase: Single-Phase
- Full Load Runtime (min.): 2 minutes (5400 watts)
- Half Load Runtime (min.): 8.5 minutes (2700 watts)
- Expandable Battery Runtime: Runtime is expandable with external battery packs
- External Battery Pack Compatibility: BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; BP192V5RT2U(limit 1)
- DC System Voltage (VDC): 192
- Battery Recharge Rate (Included Batteries): 6 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge: RBC5-192
- Battery Access: Front panel battery access door
- Battery Replacement Description: Hot-swappable, user replaceable internal batteries
- Expandable Runtime: Yes
- Voltage Regulation Description: Online, double-conversion power conditioning
- Overvoltage Correction: Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
- Undervoltage Correction: Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
- Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
- Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
- Alarm Cancel Operation: Alarm cancel switch
- Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
- LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
- UPS AC Suppression Response Time: Instantaneous
- EMI / RFI AC Noise Suppression: Yes
- Included Mounting Accessory Description: 4 post rackmount installation accessories included
- Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
- Primary Form Factor: Rackmount
- UPS Power Module Dimensions (hwd, in.): 6.85 x 17.5 x 20.67
- Rack Height (U Spaces): 4
- Maximum Device Depth (in.): 20.7
- Minimum Required Rack Depth (inches): 28.7
- UPS Power Module Weight (lbs.): 116.2
- UPS Power Module Weight (kg): 52.71
- UPS Shipping Dimensions (hwd / in.): 12.7 x 23.6 x 29.1
- Shipping Weight (lbs.): 157
- Cooling Method: Fans
- UPS Housing Material: Steel
- Minimum Required Rack Depth (mm): 729
- Primary UPS Height (mm): 174
- Primary UPS Width (mm): 444
- Primary UPS Depth (mm): 525
- Shipping Height (mm): 323
- Shipping Width (mm): 599
- Shipping Depth (mm): 739
- Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load): 1767
- AC Economy Mode BTU / Hr. (Full Load): 768
- Battery Mode BTU / Hr. (Full Load): 2279
- AC Mode Efficiency Rating (100% Load): 90%
- AC Economy Mode Efficiency Rating (100% Load): 96%
- Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
- Audible Noise: 60 dBA at front side 1 meter
- Operating Elevation (msnm): 0-3000 m
- Communications Interface: USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
- Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
- Network Monitoring Port Description: Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
- PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable: USB, DB9 serial and EPO cables included
- WatchDog Compatibility: Yes
- Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
- Transfer Time (Economy Mode): 8 ms. typical power failure response in optional economy mode
- Low Voltage Transfer to Battery Power (Setpoint): 156V (full load) / 100V (50% load or less, derates linearly)
- High Voltage Transfer to Battery Power (Setpoint): 280V (full load) / 300V (90% load or less)
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
- Green Energy-Saving Features: High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); CE; Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
- UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
- Product Warranty Period (Worldwide): 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance
- Downloads: ""
- Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240-230v-6kva-5.4kw-double-conversion-ups-4u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial-bypass-switch-hardwire~SU6000RT4UHVHW/
- Packaging
- Certifications
- Details: "Overview\nFeaturing true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UHVHW provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems in high-voltage environments. The SU6000RT4UHVHW has a 6kVA\/5400W capacity and hardwire output.\n\nWith its detachable PDU with bypass switch, the SU6000RT4UHVHW is easily hot-swappable by a user of any skill setno need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation.\n\nUPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHVHWs runtime can be expanded with optional external battery packs.\n\nThe SU6000RT4UHVHW features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.\n\nAn LCD display with LED indicators enables IT personnel to operating modes and conditions. The LCD\/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.\n\nThe SU6000RT4UHVHW features a USB port and a DB9 ports for comprehensive network power monitoring and control. Network management card options available.\n\nThe unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory.\n\nThe SU6000RT4UHVHW comes with$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment."
- List price: No