Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartOnline 208/240 & 120V 6kVA 5.4kW Double-Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, Hardwire
$3,474.57

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU6000RT4UTFHW
Sku:
147703
UPC:
0037332157225
Overview Tripp Lite SU6000RT4UTFHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 6U rack/tower compatible configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports hot-swappable UPS power module replacement with no interruption to connected equipment. 4U UPS power module and included 2U low-voltage transformer install in only 6 rack spaces total (6U) with a maximum installed depth of only 21.8 in. / 55.3 cm. Maintains full-time sine wave output within 2% of selectable 208/240V and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without userinteraction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional network management card options. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire input. Hardwire UPS output, plus 1 L6-30R, 8 5-15/20R and 4 5-15R outlets. External battery packs are field replaceable and hot swappable.$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)

Specifications

Additional Information

  • UPC: 0037332157225
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 6000
  • Output kVA Capacity (kVA): 6.0
  • Output Watt Capacity (Watts): 5400
  • Output kW Capacity (kW): 5.4
  • Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared
  • Power Factor: 0.9
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 120V; 208V; 240V
  • Nominal Voltage Details: This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)
  • Frequency Compatibility: 60 Hz
  • Frequency Compatibility Details: Output frequency regulation +/- 0.05Hz (free running)
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: (4) 5-15R; (8) 5-15/20R; (1) L6-30R; Hardwire
  • Output Receptacle Details: Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
  • Output Circuit Breakers: Low voltage 20A breakers on the transformer module protect 4 5-15/20R outlets each; Low voltage 15A breakers protect 2 5-15/20R outlets each
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
  • Nominal Input Voltage(s) Supported: 208V AC; 240V AC
  • Nominal Input Voltage Description: Factory configured to 208V
  • UPS Input Connection Type: Hardwire
  • UPS Input Connection Description: 3 wire single phase input (L1, L2, G)
  • Recommended Electrical Service: 40A (200/208v); 30A (220/230/240v)
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 2 minutes (5400 watts)
  • Half Load Runtime (min.): 8.5 minutes (2700 watts)
  • Expandable Battery Runtime: Runtime is expandable with external battery packs
  • External Battery Pack Compatibility: BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; BP192V5RT2U(limit 1)
  • DC System Voltage (VDC): 192
  • Battery Recharge Rate (Included Batteries): 6 hours from 10% to 90% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: RBC5-192
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable internal batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
  • Undervoltage Correction: Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
  • Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
  • Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
  • Alarm Cancel Operation: Alarm cancel switch
  • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
  • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Included Mounting Accessory Description: 4 post rackmount installation accessories included (2 sets)
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
  • Optional Mounting Accessory Notes: 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate UPS and transformer components
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 6.85 x 17.5 x 20.7
  • Rack Height (U Spaces): 6
  • Maximum Device Depth (in.): 21.8
  • Minimum Required Rack Depth (inches): 28.7
  • UPS Power Module Weight (lbs.): 116.2
  • UPS Power Module Weight (kg): 52.71
  • Stepdown Transformer Dimensions (hwd / in.): 3.5 x 17.5 x 21.8
  • Stepdown Transformer Weight (lbs.): 72.6
  • UPS Shipping Dimensions (hwd / in.): 22.2 x 23.6 x 29.1
  • Shipping Weight (lbs.): 232.1
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 729
  • Stepdown Transformer Height (mm): 89
  • Stepdown Transformer Width (mm): 444
  • Stepdown Transformer Depth (mm): 554
  • Primary UPS Height (mm): 174
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 526
  • Shipping Height (mm): 564
  • Shipping Width (mm): 599
  • Shipping Depth (mm): 739
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 1767
  • AC Economy Mode BTU / Hr. (Full Load): 768
  • Battery Mode BTU / Hr. (Full Load): 2279
  • AC Mode Efficiency Rating (100% Load): 90%
  • AC Economy Mode Efficiency Rating (100% Load): 96%
  • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
  • Audible Noise: 60 dBA at front side 1 meter
  • Operating Elevation (msnm): 0-3000 m
  • Communications Interface: USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB, DB9 serial and EPO cables included
  • WatchDog Compatibility: Yes
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Transfer Time (Economy Mode): 8ms. typical power failure response in optional economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): 156V (full load) / 100V (50% load or less, derates linearly)
  • High Voltage Transfer to Battery Power (Setpoint): 280V (full load) / 300V (90% load or less)
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
  • Green Energy-Saving Features: High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
  • UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240-120v-6kva-5.4kw-double-conversion-ups-6u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial-bypass-switch-hardwire~SU6000RT4UTFHW/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite SU6000RT4UTFHW 6000VA \/ 6kVA \/ 5400 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 6U rack\/tower compatible configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports hot-swappable UPS power module replacement with no interruption to connected equipment. 4U UPS power module and included 2U low-voltage transformer install in only 6 rack spaces total (6U) with a maximum installed depth of only 21.8 in. \/ 55.3 cm. Maintains full-time sine wave output within 2% of selectable 208\/240V and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without userinteraction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional network management card options. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED \/ LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire input. Hardwire UPS output, plus 1 L6-30R, 8 5-15\/20R and 4 5-15R outlets. External battery packs are field replaceable and hot swappable.$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)"
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...