37332125972
Overview Requiring only two rack spaces (2U) in a standard rack enclosure, Tripp Lite's SU1500RTXL2Ua SmartOnline UPS System protects connected equipment against data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. Featuring true on-line operation with pure sine wave output and zero transfer time to battery, it provides the highest level of power protection for mission-critical equipment. Internal batteries support connected equipment during blackouts, and runtime is expandable with optional external battery packs. The SU1500RTXL2Ua has six outlets arranged in two individually controllable load banks that can be used to reboot select equipment on demand or maximize battery runtime for mission-critical equipment. USB and DB9 communication ports support messaging of detailed UPS operational parameters and line power status. Included PowerAlert UPS monitoring and unattended shutdown software provides management support for an unlimited number of network UPS systems.

Specifications

Additional Information

  • UPC: 37332125972
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 1500
  • Output kVA Capacity (kVA): 1.5
  • Output Watt Capacity (Watts): 1200
  • Output kW Capacity (kW): 1.2
  • Output Capacity Details: OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
  • Power Factor: 0.8
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 100V; 110V; 120V
  • Nominal Voltage Details: 120V default
  • Frequency Compatibility: 50 / 60 Hz
  • Frequency Compatibility Details: Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: (6) 5-15R
  • Load Management Receptacles: Two switchable 5-15R load banks (bank 1 - two outlets, bank 2 - four outlets)
  • Output AC Waveform (AC Mode): Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 12A
  • Nominal Input Voltage(s) Supported: 100V AC; 110V AC; 120V AC
  • UPS Input Connection Type: 5-15P
  • Input Circuit Breakers: 20A
  • UPS Input Cord Length (ft.): 10
  • Recommended Electrical Service: 15A 120V
  • Input Phase: Single-Phase
  • Input Frequency: 50/60Hz +/-5%
  • Full Load Runtime (min.): 5 min. (1200w)
  • Half Load Runtime (min.): 14 min. (600w)
  • Expandable Battery Runtime: Extended runtime supported via optional external battery packs
  • External Battery Pack Compatibility: BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible)
  • DC System Voltage (VDC): 48
  • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 80% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: RBC94-2U
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: 2% output voltage regulation during overvoltages to 150
  • Undervoltage Correction: 2% output voltage regulation during undervoltages to 80
  • Severe Undervoltage Correction: 2% output voltage regulation during undervoltages to 65 (under 70% load only)
  • Switches: 2 switches control off/on power status and alarm-cancel/self-test operation
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
  • Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
  • LED Indicators: 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
  • UPS AC Suppression Joule Rating: 600
  • UPS AC Suppression Response Time: Instantaneous
  • UPS Dataline Suppression: 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
  • EMI / RFI AC Noise Suppression: Yes
  • Installation Form Factors Supported with Included Accessories: 4 post 19 inch rackmount
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITWM); Wallmount(2POSTRMKITWM); Tower(2-9USTAND)
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 3.5 x 17.5 x 19
  • Rack Height (U Spaces): 2
  • Minimum Required Rack Depth (inches): 26
  • UPS Power Module Weight (lbs.): 44.1
  • UPS Power Module Weight (kg): 20.00
  • UPS Shipping Dimensions (hwd / in.): 9.8 x 20.2 x 24
  • Shipping Weight (lbs.): 54
  • Cooling Method: Fan
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 660
  • Primary UPS Height (mm): 89
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 483
  • Shipping Height (mm): 249
  • Shipping Width (mm): 513
  • Shipping Depth (mm): 610
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 612
  • AC Economy Mode BTU / Hr. (Full Load): 216
  • Battery Mode BTU / Hr. (Full Load): 667
  • AC Economy Mode Efficiency Rating (100% Load): 95%
  • Communications Interface: USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB and DB9 cabling included
  • WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Low Voltage Transfer to Battery Power (Setpoint): 80V (100% load), 65V ( <70% load)
  • High Voltage Transfer to Battery Power (Setpoint): 150
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
  • Green Energy-Saving Features: High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-120v-1.5kva-1.2kw-double-conversion-ups-2u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial~SU1500RTXL2UA/
  • Packaging

  • Certifications

  • Details: "Overview\nRequiring only two rack spaces (2U) in a standard rack enclosure, Tripp Lite's SU1500RTXL2Ua SmartOnline UPS System protects connected equipment against data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. Featuring true on-line operation with pure sine wave output and zero transfer time to battery, it provides the highest level of power protection for mission-critical equipment. Internal batteries support connected equipment during blackouts, and runtime is expandable with optional external battery packs. The SU1500RTXL2Ua has six outlets arranged in two individually controllable load banks that can be used to reboot select equipment on demand or maximize battery runtime for mission-critical equipment. USB and DB9 communication ports support messaging of detailed UPS operational parameters and line power status. Included PowerAlert UPS monitoring and unattended shutdown software provides management support for an unlimited number of network UPS systems."