SmartOnline 120V 1.5kVA 1.35kW Double-Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9
Specifications
Additional Information
- UPC: 37332168610
- Manufacturer: TRIPPLITE
- Specifications
- Output Volt Amp Capacity (VA): 1500
- Output kVA Capacity (kVA): 1.5
- Output Watt Capacity (Watts): 1350
- Output kW Capacity (kW): 1.35
- Output Capacity Details: ON LINE MODE: Maximum output capacity ratings is reduced to 1215 watts at 115V nominal and 1080 watts at 100V nominal; FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts / 115V 850 watts / 110V 804 watts / 100V 756 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
- Power Factor: 0.9
- Crest Factor: 3:1
- Nominal Output Voltage(s) Supported: 100V; 110V; 115V; 120V; 127V
- Nominal Voltage Details: 120V factory-default nominal voltage; Less than 3% THD for linear loads and less than 5% for non-linear computer loads
- Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
- Frequency Compatibility Details: ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.
- Output Voltage Regulation (Line Mode): +/- 2%
- Output Voltage Regulation (Economy Line Mode): +/- 10%
- Output Voltage Regulation (Battery Mode): +/- 3%
- Output Receptacles: (6) 5-15R
- Load Management Receptacles: Two switchable three-outlet 5-15R load banks
- Output AC Waveform (AC Mode): Pure Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Rated input current (Maximum Load): 12A
- Nominal Input Voltage(s) Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
- Nominal Input Voltage Description: 120V factory default
- UPS Input Connection Type: 5-15P
- Input Circuit Breakers: 20A
- UPS Input Cord Length (ft.): 10
- Recommended Electrical Service: 15A 120V
- Input Phase: Single-Phase
- Full Load Runtime (min.): 4.2 min. (1350w)
- Half Load Runtime (min.): 14 min. (675w)
- Expandable Battery Runtime: Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility: BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible)
- Expandable Runtime Description: Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
- DC System Voltage (VDC): 48
- Battery Recharge Rate (Included Batteries): Less than 3 hours recharge to 90%; Add 6 hours per BP48V27-2US (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge: RBC94-2U
- Battery Access: Front panel battery access
- Battery Replacement Description: Hot-swappable, user replaceable batteries
- Expandable Runtime: Yes
- Voltage Regulation Description: Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages
- Overvoltage Correction: Corrects overvoltages to 150V (0-100% load)
- Undervoltage Correction: Corrects undervoltages to 100V at full load (90V at 100V nominal)
- Severe Undervoltage Correction: Corrects brownouts to 70V (70% load) & 55V (33% load)
- Front Panel LCD Display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
- Switches: 2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
- Alarm Cancel Operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
- Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
- LED Indicators: 7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status
- UPS AC Suppression Joule Rating: 570
- UPS AC Suppression Response Time: Instantaneous
- UPS Dataline Suppression: 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
- EMI / RFI AC Noise Suppression: Yes
- Included Mounting Accessory Description: Includes 4 post rackmount installation accessories
- Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITWM); Wallmount(2POSTRMKITWM); Tower(2-9USTAND)
- Primary Form Factor: Rackmount
- UPS Power Module Dimensions (hwd, in.): 3.5 x 17.5 x 18.5
- Rack Height (U Spaces): 2
- Minimum Required Rack Depth (inches): 25.5
- UPS Power Module Weight (lbs.): 45.2
- UPS Power Module Weight (kg): 20.50
- UPS Shipping Dimensions (hwd / in.): 9.5 x 20 x 24
- Shipping Weight (lbs.): 57.8
- Cooling Method: Fan
- UPS Housing Material: Steel
- Minimum Required Rack Depth (mm): 648
- Primary UPS Height (mm): 89
- Primary UPS Width (mm): 444
- Primary UPS Depth (mm): 470
- Shipping Height (mm): 241
- Shipping Width (mm): 508
- Shipping Depth (mm): 610
- Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range: +5 to +122 degrees Fahrenheit / -20 to +40 degrees Celsius with batteries; -13 to +131 Fahrenheit / -25 to +55 degrees Celsius without batteries
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load): 455
- AC Economy Mode BTU / Hr. (Full Load): 294
- Battery Mode BTU / Hr. (Full Load): 559
- AC Economy Mode Efficiency Rating (100% Load): 94%
- Operating Elevation (ft.): 0-3000m / 0-10,000 ft.
- Audible Noise: 45 dBA at 1m front side
- Operating Elevation (msnm): 0 - 3000 m
- Communications Interface: USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
- Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
- Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
- PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable: USB and DB9 cabling included
- WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Transfer Time: Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode
- Low Voltage Transfer to Battery Power (Setpoint): 100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load
- High Voltage Transfer to Battery Power (Setpoint): 150
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
- Green Energy-Saving Features: High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); ENERGY STAR Qualified
- Product Warranty Period (Worldwide): 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance
- Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/933156.pdf","title":"Owner's Manual for Single-Phase Online Rack UPS with Built-in LCD 933156"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU1500RTXLCD2U-Runtime-Chart-EN.pdf","title":"SU1500RTXLCD2U runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Flyer\/UPS-Output-Voltage-Selector-Instructions.pdf","title":"UPS System Output Voltage Selection Instructions Flyer (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Flyer\/Tripp-Lite-UPS-Battery-Backup-for-Security-Systems-Flyer-EN.PDF","title":"Tripp Lite UPS Battery Backup for Security Systems Flyer 953463 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/su1500rtxlcd2u-smartonline-ups-system\/52166","title":"https:\/\/www.tripplite.com\/video\/su1500rtxlcd2u-smartonline-ups-system\/52166"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/5037","title":"Download images for this product"}]}
- Manufacturer Product URL: https://www.tripplite.com/smartonline-120v-1.5kva-1.35kw-double-conversion-ups-2u-rack-tower-extended-run-snmpwebcard-option-lcd-display-usb-db9-serial~SU1500RTXLCD2U/
- Packaging
- Certifications
- Details: "Overview\nTripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) with Transformerless, IGBT technology maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +\/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and slot for network management card options. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. PowerAlert UPS monitoring software is available via free download. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. LED\/LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs."
- List price: No