Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartOnline 3-Phase 120/208V 20kVA 16kW Double-Conversion UPS, Extended Run, 5 internal batteries, Network Card Options, Tower, DB9 Serial, Hardwire
$11,529.99

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU20K3/3XR5
Sku:
205518
UPC:
37332136770
Overview Tripp Lite's SU20K3/3XR5 20kVA SmartOnline 3-Phase Intelligent, True On-Line Extended Runtime UPS System has been redesigned to save valuable space and simplify runtime scalability. Power and battery components are combined into a single, small-footprint module (the smallest in its class). A robust internal battery runtime capability can be easily extended by installing additional optional internal battery packs through the convenient front panel access door. The SU20K3/3XR5 features a large internal battery compartment that contains more internal batteries than the equivalent standard-run model (SU20K3/3) and more space to add additional optional internal battery packs to extend runtime. The SU20K3/3XR5 provides mission-critical equipment with the highest level of power protection available. Large capacity 20,000VA/16,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. IGBT inverter technology produces output power with <3% THD (total harmonic distortion), allowing connected equipment to perform at its peak. A 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands. Extremely efficient operation saves money by lowering electricity consumption. Hardwire input and output connections. SU20K3/3XR5 features 120/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 96-144/166-250V AC. Frequency is 50 or 60 Hz (auto-selectable). SU20K3/3XR5 includes internal power and battery components in a single small-footprint tower module. Battery support can be extended with additional internal battery packs. A manual bypass switch as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power when the UPS requires maintenance. Three built-in communication ports (RS-232, contact closure and AS-400) work with PowerAlert Software, available via free download, to simultaneously provide shutdown commands and reporting on multiple servers without the need for costly accessories. An accessory slot accepts an optional internal network managment card. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions. A start-up service program is recommended to enhance the reliability of the installation.

Specifications

Additional Information

  • UPC: 37332136770
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 20000
  • Output kVA Capacity (kVA): 20
  • Output Watt Capacity (Watts): 16000
  • Output kW Capacity (kW): 16
  • Power Factor: 0.8
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 120V; 208V
  • Frequency Compatibility: 50 / 60 Hz
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: Hardwire
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 60A (per phase, online)
  • Nominal Input Voltage(s) Supported: 120/208V 3-PH Wye
  • Nominal Input Voltage Description: 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
  • UPS Input Connection Type: Hardwire
  • Input Phase: 3-Phase
  • Full Load Runtime (min.): 17 min. (16kw)
  • Half Load Runtime (min.): 42 min. (8kw)
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
  • External Battery Pack Compatibility: SURBC2030; SUBF2030(holds 4 SURBC2030)
  • Expandable Runtime Description: Includes a battery housing with space for 3 internal SURBC2030 battery packs for extended runtime. Additional runtime capacity is available by adding SUBF2030 and additional SURBC2030 batteries - see runtime chart for specific recommendations
  • DC System Voltage (VDC): 240
  • Battery Recharge Rate (Included Batteries): 2 - 4 hours from 10% to 90%
  • Internal UPS Replacement Battery Cartridge: SURBC2030
  • Battery Access: Front panel internal battery access door
  • Battery Replacement Description: Hot-swappable, replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: Maintains continuous operation without using battery power during overvoltages to 144 / 250 (3-Phase, 4-Wire, wye), reducing output within 2% of nominal
  • Undervoltage Correction: Maintains continuous operation without using battery power during brownout / undervoltage conditions to 96 / 166 (3-Phase, 4-Wire, wye)
  • Front Panel LCD Display: SELECTABLE LCD DISPLAY: indicates a wide range of UPS operational and fault/warning conditions including operational mode, alarm/shutdown conditions, input/output voltage/frequency, battery voltage, load percentage and more (see manual)
  • Switches: "ON" button turns UPS's inverter ON. "OFF" button turns UPS's inverter OFF. "Select" Button browses through items displayed on LCD screen. "Enter" button selects items displayed on LCD screen. "Select" and "Enter" buttons used simultaneously mute UPS alarms. "Battery Start" Switch cold starts the inverter. "Emergency Power Off" button turns UPS output OFF and disables Bypass output. "Manual Bypass" switch bypasses the UPS's inverter during maintenance.
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
  • Audible Alarm: Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more
  • LED Indicators: 7 LED DISPLAY: AC input, bypass input, AC-DC charger, DC-AC inverter, AC output, bypass operation and battery operation
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Joule Rating: 2032
  • AC Suppression Response Time: Instantaneous
  • Installation Form Factors Supported with Included Accessories: Tower
  • Primary Form Factor: Tower
  • UPS Power Module Dimensions (hwd, in.): 50.9 x 19.5 x 36.8
  • UPS Power Module Weight (lbs.): 979
  • UPS Power Module Weight (kg): 444.07
  • UPS Shipping Dimensions (hwd / in.): 59.6 x 28 x 44.4
  • Shipping Weight (lbs.): 1133
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Primary UPS Height (mm): 1293
  • Primary UPS Width (mm): 495
  • Primary UPS Depth (mm): 935
  • Shipping Height (mm): 1514
  • Shipping Width (mm): 711
  • Shipping Depth (mm): 1128
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 5 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 5355
  • Battery Mode BTU / Hr. (Full Load): 4413
  • Communications Interface: DB9 Serial; Contact closure; Slot for SNMP/Web interface
  • Network Monitoring Port Description: RS232, contact closure and AS400 monitoring ports are supported by 3 separate DB9 ports
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: DB9 cabling included
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Low Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation during undervoltages as low as 96 / 166V AC (3-Phase, 4-Wire, wye). Below this point, output is maintained utilizing battery reserves.
  • High Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation during overvoltages as high as 144 / 250V AC (3-Phase, 4-Wire, wye). Above this point, output is maintained utilizing battery reserves.
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
  • Product Warranty Period (U.S. & Canada): 1-year limited warranty
  • Product Warranty Period (International): 2-year limited warranty
  • Product Warranty Period (Mexico): 1-year limited warranty
  • Product Warranty Period (Puerto Rico): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932653.pdf","title":"Owner's Manual for Battery Module Compartment Model: SUBF2030 932653 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932624.pdf","title":"Owner's Manual for SmartOnline 3-Phase 20kVA & 30kVA UPS 932624"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932652.pdf","title":"Unpacking Instructions 932652"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU20K3-3XR5-Runtime-Chart-EN.pdf","title":"SU20K3\/3XR5 runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/SmartOnline-3-Phase-UPS-Systems-Brochure-95-33E5-English.PDF","title":"SmartOnline 3-Phase UPS Systems Brochure 9533E5 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/3607","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-3-phase-120-208v-20kva-16kw-double-conversion-ups-extended-run-5-internal-batteries-snmpwebcard-option-tower-db9-serial-hardwire~SU20K33XR5/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite's SU20K3\/3XR5 20kVA SmartOnline 3-Phase Intelligent, True On-Line Extended Runtime UPS System has been redesigned to save valuable space and simplify runtime scalability. Power and battery components are combined into a single, small-footprint module (the smallest in its class). A robust internal battery runtime capability can be easily extended by installing additional optional internal battery packs through the convenient front panel access door. The SU20K3\/3XR5 features a large internal battery compartment that contains more internal batteries than the equivalent standard-run model (SU20K3\/3) and more space to add additional optional internal battery packs to extend runtime. The SU20K3\/3XR5 provides mission-critical equipment with the highest level of power protection available. Large capacity 20,000VA\/16,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. IGBT inverter technology produces output power with <3% THD (total harmonic distortion), allowing connected equipment to perform at its peak. A 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands. Extremely efficient operation saves money by lowering electricity consumption. Hardwire input and output connections. SU20K3\/3XR5 features 120\/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 96-144\/166-250V AC. Frequency is 50 or 60 Hz (auto-selectable). SU20K3\/3XR5 includes internal power and battery components in a single small-footprint tower module. Battery support can be extended with additional internal battery packs. A manual bypass switch as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power when the UPS requires maintenance. Three built-in communication ports (RS-232, contact closure and AS-400) work with PowerAlert Software, available via free download, to simultaneously provide shutdown commands and reporting on multiple servers without the need for costly accessories. An accessory slot accepts an optional internal network managment card. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination LCD\/LED display alerts users to a variety of UPS operational modes and conditions. A start-up service program is recommended to enhance the reliability of the installation."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...