Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartOnline 120V 3kVA 2.5kW Double-Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial
$1,259.64

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU3000RTXL2U
Sku:
12678
UPC:
0037332144577
Overview 3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 26 inches (66cm). Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 100/110/115/120/127V output with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 70V and overvoltages to 144V. Up to 97% efficiency in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA 5-15/20R and NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and slot for network management card options. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. PowerAlert UPS monitoring software is available via free download. Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in rackmount or tower configurations. Includes 4 post rackmount accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware accessories available. Field replaceable, hot swappable internal batteries and external battery packs.$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).

Specifications

Additional Information

  • UPC: 0037332144577
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 3000
  • Output kVA Capacity (kVA): 3
  • Output Watt Capacity (Watts): 2500
  • Output kW Capacity (kW): 2.5
  • Output Capacity Details: Max output is reduced to 2400W at 100V, 110V and 115V nominal settings OVERLOAD CAPACITY: Supports inverter operation up to 100% load continuously, 120% for 30 seconds, 150% for 10 seconds and >150% for 0.1 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
  • Power Factor: 0.83
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 100V; 110V; 115V; 120V; 127V
  • Nominal Voltage Details: 120V default
  • Frequency Compatibility: 50 / 60 Hz
  • Frequency Compatibility Details: Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 25% during frequency conversion operation.
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): -12%, + 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: (6) 5-15/20R; (1) L5-30R
  • Load Management Receptacles: Two switchable three-outlet load banks
  • Output Circuit Breakers: 20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 24A
  • Nominal Input Voltage(s) Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
  • UPS Input Connection Type: L5-30P
  • Recommended Electrical Service: 30A 120V
  • Input Cord Length (ft.): 10
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 6 min. (2500w)
  • Half Load Runtime (min.): 15 min. (1250w)
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
  • External Battery Pack Compatibility: BP72V15-2U(limit 1); BP72V28RT-3U(multi-pack compatible); BP72V18-2US(multi-pack compatible)
  • DC System Voltage (VDC): 72
  • Battery Recharge Rate (Included Batteries): Less than 4.8 hours from 10% to 90% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: RBC96-2U
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: 2% output voltage regulation during overvoltages to 144
  • Undervoltage Correction: 2% output voltage regulation during undervoltages to 80
  • Severe Undervoltage Correction: 2% output voltage regulation during undervoltages to 70V (under 66% load only) or 60V (under 33% load only)
  • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
  • Audible Alarm: Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
  • LED Indicators: 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
  • UPS AC Suppression Joule Rating: 504 joules
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Response Time: Instantaneous
  • Included Mounting Accessory Description: Includes 4 post rackmount installation accessories
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITWM); Tower(2-9USTAND)
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 3.5 x 17.3 x 26
  • Rack Height (U Spaces): 2
  • Minimum Required Rack Depth (inches): 37
  • UPS Power Module Weight (lbs.): 68.8
  • UPS Power Module Weight (kg): 31.21
  • UPS Shipping Dimensions (hwd / in.): 9 x 22 x 32.8
  • Shipping Weight (lbs.): 78.3
  • Cooling Method: Fan
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 940
  • Primary UPS Height (mm): 89
  • Primary UPS Width (mm): 439
  • Primary UPS Depth (mm): 660
  • Shipping Height (mm): 229
  • Shipping Width (mm): 559
  • Shipping Depth (mm): 833
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 1000
  • AC Economy Mode BTU / Hr. (Full Load): 241
  • Battery Mode BTU / Hr. (Full Load): 1507
  • AC Mode Efficiency Rating (100% Load): 89%
  • AC Economy Mode Efficiency Rating (100% Load): 97%
  • Communications Interface: USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX
  • Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB and DB9 cabling included
  • WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Low Voltage Transfer to Battery Power (Setpoint): 80V (100% load), 70V (66% load), 60V (33% load)
  • High Voltage Transfer to Battery Power (Setpoint): 144
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
  • Green Energy-Saving Features: High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932835.pdf","title":"Owner's Manual for SmartOnline UPS 932835"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU3000RTXL2U-Runtime-Chart-EN.pdf","title":"SU3000RTXL2U runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Flyer\/UPS-Output-Voltage-Selector-Instructions.pdf","title":"UPS System Output Voltage Selection Instructions Flyer (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other\/case-study\/NOC-Case-Study-EN.pdf","title":"Tripp Lite Protects NOC Case Study - Remotely Monitored Power Management and Protection (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/su3000rtxl2u-smartonline-ups-system\/48980","title":"https:\/\/www.tripplite.com\/video\/su3000rtxl2u-smartonline-ups-system\/48980"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4210","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-120v-3kva-2.5kw-double-conversion-ups-2u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial~SU3000RTXL2U/
  • Packaging

  • Certifications

  • Details: "Overview\n3000VA \/ 3kVA \/ 2500 watt on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 26 inches (66cm). Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 100\/110\/115\/120\/127V output with +\/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 70V and overvoltages to 144V. Up to 97% efficiency in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA 5-15\/20R and NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and slot for network management card options. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. PowerAlert UPS monitoring software is available via free download. Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in rackmount or tower configurations. Includes 4 post rackmount accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware accessories available. Field replaceable, hot swappable internal batteries and external battery packs.$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...