Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartOnline 208/240 & 120V 6kVA 4.2kW Double-Conversion UPS, 9U Rack/Tower, Extended Run, Network Card Slot, DB9, Bypass Switch, Hardwire
$4,000.00

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SU6000RT3U
Sku:
250520
UPC:
37332121417
Overview Tripp Lite SU6000RT3U on-line, double-conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower/rackmount housing. In a rack configuration, the power module, step-down transformer, and battery pack occupy only 3 rack spaces each (9U total). Upright tower placement of entire system supported with included tower stands. Large capacity 6000VA/4200 watt power module double-conversion technology converts raw input AC to DC, then resynthesizes it back to perfect sine wave AC output within 2% of user-selectable 208V/240V and 120V AC output voltages. Frequency regulation locks output power to 50/60Hz (+/-0.2 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed uptime and compatibility with all equipment types. Hardwire input and output connections support a variety of permanent or plug-in power connections. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Battery support can be extended through the addition of external battery packs. Includes accessory slot for optional monitoring and management cards, plus DB9 contact-closure, and DB9 enhanced serial monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data.

Specifications

Additional Information

  • UPC: 37332121417
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 6000
  • Output kVA Capacity (kVA): 6
  • Output Watt Capacity (Watts): 4200
  • Output kW Capacity (kW): 4.2
  • Output Capacity Details: Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 90% or less
  • Power Factor: 0.7
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 120V; 208V; 240V
  • Nominal Voltage Details: Voltage selection via front panel LCD interface
  • Frequency Compatibility: 50 / 60 Hz
  • Frequency Compatibility Details: Output frequency matches input nominal on startup
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: Hardwire
  • Output Receptacle Backplate Options: Optional backplates SUPDM12 (for 208v nominal), SUPDM14 (for 240v nominal), SUPDM16 (for 208v nominal) add low and high voltage outlets, plus L6-30P input cord
  • Output Circuit Breakers: 40A double-pole
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 30A
  • Nominal Input Voltage(s) Supported: 208V AC; 240V AC
  • UPS Input Connection Type: Hardwire
  • UPS Input Connection Description: 3 wire single phase input (L1, L2, G); optional, country-specific backplates SUPDM12 (for 208v nominal), SUPDM14 (for 240v nominal), SUPDM16 (for 208v nominal) add low and high voltage outlets, plus L6-30P input cord
  • Input Circuit Breakers: 40A double-pole
  • Recommended Electrical Service: 30A 208V or 240V
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 8 min. (4200w)
  • Half Load Runtime (min.): 20 min. (2100w)
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
  • External Battery Pack Compatibility: BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH
  • DC System Voltage (VDC): 240
  • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 80% (typical, full load discharge)
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: 2% output voltage regulation during overvoltages to 276
  • Undervoltage Correction: 2% output voltage regulation during undervoltages to 156
  • Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
  • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled transformer includes bypass switch to enable hot-swap UPS power module replacement
  • Alarm Cancel Operation: Alarm cancel switch
  • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
  • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Output Isolation Transformer: 120V output includes load isolation transfomer protection
  • Included Mounting Accessory Description: 3 sets of adjustable 4 post rack rails included (for UPS, transformer and battery pack components); 2-9USTAND tower kit included (supports up to 9U in tower format)
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD)
  • Optional Mounting Accessory Notes: 3 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate UPS, transformer and battery pack
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 5.2 x 17.5 x 26
  • Rack Height (U Spaces): 9
  • Maximum Device Depth (in.): 26
  • Minimum Required Rack Depth (inches): 33
  • UPS Power Module Weight (lbs.): 43.8
  • UPS Power Module Weight (kg): 19.87
  • UPS Dimensions Details: Includes 3U UPS/power module, 3U stepdown transformer and 3U battery pack
  • Stepdown Transformer Dimensions (hwd / in.): 5.2 x 17.5 x 26
  • Stepdown Transformer Weight (lbs.): 90
  • Included Battery Pack Dimensions (hwd / in.): 5.2 x 17.5 x 25
  • Included Battery Pack Weight (lbs.): 136.5
  • UPS Shipping Dimensions (hwd / in.): 36 x 24 x 35
  • Shipping Weight (lbs.): 436
  • Cooling Method: Fan
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 838
  • Stepdown Transformer Height (mm): 132
  • Stepdown Transformer Width (mm): 444
  • Stepdown Transformer Depth (mm): 660
  • Primary UPS Height (mm): 132
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 660
  • Shipping Height (mm): 914
  • Shipping Width (mm): 610
  • Shipping Depth (mm): 889
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 1418
  • Battery Mode BTU / Hr. (Full Load): 1593
  • AC Mode Efficiency Rating (100% Load): 91%
  • AC Economy Mode Efficiency Rating (100% Load): 96%
  • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
  • Audible Noise: 53dBA At Front Side 1 Meter
  • Operating Elevation (msnm): 0-3000 m
  • Communications Interface: DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: RS232 and contact closure communications are located on two separate DB9 ports
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: DB9 cable included
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Transfer Time (Economy Mode): 8ms. typical power failure response in optional economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): 156
  • High Voltage Transfer to Battery Power (Setpoint): 276
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • Economy Mode Operation: Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
  • High Availability UPS Features: Automatic inverter bypass; Manual bypass switch; Hot swappable UPS power module; Hot swappable batteries
  • Green Energy-Saving Features: High efficiency economy mode operation; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina)
  • Product Warranty Period (Worldwide): 2-year limited warranty
  • Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932188.pdf","title":"Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU6000RT3U-Runtime-Chart-EN.pdf","title":"SU6000RT3U runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other\/case-study\/Tripp-Lite-Protects-Cisco-Digital-Media-System-Case-Study-EN.pdf","title":"Tripp Lite Protects Cisco Digital Media System Case Study - Cisco Digital Media System Protection (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932487.PDF","title":"Owner's Manual for BP Battery 932487 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/su6000rt3u-smartonline-ups-system\/60565","title":"https:\/\/www.tripplite.com\/video\/su6000rt3u-smartonline-ups-system\/60565"},{"url":"https:https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731","title":"https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/32","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-208-240-120v-6kva-4.2kw-double-conversion-ups-9u-rack-tower-extended-run-snmpwebcard-option-db9-bypass-switch-hardwire~SU6000RT3U/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite SU6000RT3U on-line, double-conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower\/rackmount housing. In a rack configuration, the power module, step-down transformer, and battery pack occupy only 3 rack spaces each (9U total). Upright tower placement of entire system supported with included tower stands. Large capacity 6000VA\/4200 watt power module double-conversion technology converts raw input AC to DC, then resynthesizes it back to perfect sine wave AC output within 2% of user-selectable 208V\/240V and 120V AC output voltages. Frequency regulation locks output power to 50\/60Hz (+\/-0.2 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed uptime and compatibility with all equipment types. Hardwire input and output connections support a variety of permanent or plug-in power connections. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Battery support can be extended through the addition of external battery packs. Includes accessory slot for optional monitoring and management cards, plus DB9 contact-closure, and DB9 enhanced serial monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...