Overview Tripp Lite's SU60K (60kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In an N+1 configuration, the SU60K features three self-contained, redundant 20kVA power modules that can be hot-swapped (with the load powered) if maintenance is required. Connect two SU60K models in parallel (1+1 configuration) to provide fail-safe redundancy (two 60kVA models supporting a 60kVA load) or to increase capacity (two 60kVA models supporting an 120kVA load). The SU60K provides mission-critical equipment with the highest level of power protection available. Large capacity 60,000VA/48,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. The SU60K's high input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology create less than 3% input Total Harmonic Distortion (THDi). With SU60K's low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to their equipment load (a 1:1 ratio). Extremely efficient operation (up to 96%) saves money by lowering electricity consumption. Hardwire input and output connections. SU60K features 120/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 94-150/163-260V AC. Frequency is 50 or 60 Hz (auto-selectable). SU60K features a single small-footprint tower power module. A stand-alone hardwired external battery module (Models BP480V26B or BP480V40C with matching battery cabinets, available separately) is required for operation and to provide battery backup support. Additional external BP480V26B or BP480V40C battery modules can be connected for extended runtime. Additional battery cabinets for extended runtime solutions also available; contact Tripp Lite for more information. A manual bypass breaker as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance. A built-in RS-232 communication port works with PowerAlert Software to provide shutdown commands and condition reporting. An accessory slot accepts an optional network management card option. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions. The LCD display includes a real-time event log screen with up to 500 events listed. A dynamic battery management screen optimizes battery function to lengthen service life and allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities. A start-up service program is recommended to enhance the reliability of the installation.

Specifications

Additional Information

  • UPC: 37332141323
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 60000
  • Output kVA Capacity (kVA): 60
  • Output Watt Capacity (Watts): 48000
  • Output kW Capacity (kW): 48
  • Power Factor: 0.8
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 120/208V 3-PH Wye
  • Frequency Compatibility: 50 / 60 Hz
  • Output Voltage Regulation (Line Mode): +/- 1%
  • Output Voltage Regulation (Battery Mode): +/- 1%
  • Output Receptacles: Hardwire
  • Output AC Waveform (AC Mode): Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 125A (per phase, online)
  • Nominal Input Voltage(s) Supported: 120/208V 3-PH Wye
  • Nominal Input Voltage Description: 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
  • UPS Input Connection Type: Hardwire
  • Input Phase: 3-Phase
  • Expandable Battery Runtime: Battery set sold separate
  • External Battery Pack Compatibility: BP480V200; BP480V26B; BP480V300; BP480V400; BP480V40C; BP480V500
  • Expandable Runtime Description: External battery pack wiring is contractor supplied
  • DC System Voltage (VDC): +/- 240VDC
  • Battery Recharge Rate (Included Batteries): Less than 4 hours from 10% to 90%
  • Battery Replacement Description: Hot-swappable, replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: Maintains continuous operation without using battery power during overvoltages to 150 / 260 (3-Phase, 4-Wire, wye), reducing output within 1% of nominal
  • Undervoltage Correction: Maintains continuous operation without using battery power during brownout / undervoltage conditions to 94 / 163 (3-Phase, 4-Wire, wye)
  • Switches: ON button turns UPS's inverter ON. OFF button turns UPS's inverter OFF. LCD Display Control Buttons browses through and selects items displayed on LCD screen. Emergency Power Off button turns UPS output OFF and disables Bypass output. Manual Bypass breaker bypasses the UPS's inverter during maintenance.
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
  • Audible Alarm: Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more
  • LED Indicators: 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Joule Rating: 4675
  • AC Suppression Response Time: Instantaneous
  • Installation Form Factors Supported with Included Accessories: Tower
  • Primary Form Factor: Tower
  • UPS Power Module Dimensions (hwd, in.): 66.9 x 20.5 x 37.7
  • UPS Power Module Weight (lbs.): 1177.5
  • UPS Power Module Weight (kg): 534.11
  • UPS Shipping Dimensions (hwd / in.): 74.8 x 28.5 x 45
  • Shipping Weight (lbs.): 1356
  • Cooling Method: Fans
  • UPS Housing Material: Steel
  • Primary UPS Height (mm): 1699
  • Primary UPS Width (mm): 521
  • Primary UPS Depth (mm): 958
  • Shipping Height (mm): 1900
  • Shipping Width (mm): 724
  • Shipping Depth (mm): 1143
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 13998
  • Battery Mode BTU / Hr. (Full Load): 14254
  • Communications Interface: DB9 Serial; Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: DB9 cabling included
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Low Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation during undervoltages as low as 94 / 163V AC (3-Phase, 4-Wire, wye). Below this point, output is maintained utilizing battery reserves.
  • High Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation during overvoltages as high as 150 / 260V AC (3-Phase, 4-Wire, wye). Above this point, output is maintained utilizing battery reserves.
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
  • Green Energy-Saving Features: High efficiency economy mode operation; Schedulable daily hours of economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
  • Product Warranty Period (U.S. & Canada): 1-year limited warranty
  • Product Warranty Period (International): 2-year limited warranty
  • Product Warranty Period (Mexico): 1-year limited warranty
  • Product Warranty Period (Puerto Rico): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932764.pdf","title":"Owner's Manual for 3-Phase UPS 932764 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU60K-Runtime-Chart-EN.pdf","title":"SU60K runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/SmartOnline-3-Phase-UPS-Systems-Brochure-95-33E5-English.PDF","title":"SmartOnline 3-Phase UPS Systems Brochure 9533E5 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/3790","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-120-208v-3-phase-wye-60kva-modular-3-phase-ups-system-on-line-double-conversion-ups-for-north-america~SU60K/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite's SU60K (60kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In an N+1 configuration, the SU60K features three self-contained, redundant 20kVA power modules that can be hot-swapped (with the load powered) if maintenance is required. Connect two SU60K models in parallel (1+1 configuration) to provide fail-safe redundancy (two 60kVA models supporting a 60kVA load) or to increase capacity (two 60kVA models supporting an 120kVA load).\n\nThe SU60K provides mission-critical equipment with the highest level of power protection available. Large capacity 60,000VA\/48,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. The SU60K's high input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology create less than 3% input Total Harmonic Distortion (THDi). With SU60K's low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to their equipment load (a 1:1 ratio). Extremely efficient operation (up to 96%) saves money by lowering electricity consumption. Hardwire input and output connections. SU60K features 120\/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 94-150\/163-260V AC. Frequency is 50 or 60 Hz (auto-selectable). SU60K features a single small-footprint tower power module. A stand-alone hardwired external battery module (Models BP480V26B or BP480V40C with matching battery cabinets, available separately) is required for operation and to provide battery backup support. Additional external BP480V26B or BP480V40C battery modules can be connected for extended runtime. Additional battery cabinets for extended runtime solutions also available; contact Tripp Lite for more information. A manual bypass breaker as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance. A built-in RS-232 communication port works with PowerAlert Software to provide shutdown commands and condition reporting. An accessory slot accepts an optional network management card option. Front panel combination LCD\/LED display alerts users to a variety of UPS operational modes and conditions. The LCD display includes a real-time event log screen with up to 500 events listed. A dynamic battery management screen optimizes battery function to lengthen service life and allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities. A start-up service program is recommended to enhance the reliability of the installation."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...