SmartOnline 208 & 120V 8kVA 7.2kW Double-Conversion UPS, 8U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, NEMA outlets
Specifications
Additional Information
- UPC: 0037332138026
- Manufacturer: TRIPPLITE
- Specifications
- Output Volt Amp Capacity (VA): 8000
- Output kVA Capacity (kVA): 8
- Output Watt Capacity (Watts): 7200
- Output kW Capacity (kW): 7.2
- Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
- Power Factor: 0.9
- Crest Factor: 3:1
- Nominal Output Voltage(s) Supported: 120V; 208V
- Nominal Voltage Details: 7200 watts total output supported; 5000 watts maximum 120V output; Add 1 additional SU5000XFMRT2U transformer for full load 120V operation; Voltage selection via front panel LCD interface; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer supports 120V output
- Frequency Compatibility: 60 Hz
- Frequency Compatibility Details: Output frequency regulation +/- 0.05Hz (free running)
- Output Voltage Regulation (Line Mode): +/- 2%
- Output Voltage Regulation (Economy Line Mode): +/- 10%
- Output Voltage Regulation (Battery Mode): +/- 2%
- Output Receptacles: (12) 5-15/20R; (4) L6-20R; (2) L6-30R
- Output Circuit Breakers: 20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x4) protect 3 5-15/20R outlets each
- Output AC Waveform (AC Mode): Pure Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Rated input current (Maximum Load): 44.2A (208V)
- Nominal Input Voltage(s) Supported: 208V AC
- UPS Input Connection Type: Hardwire
- UPS Input Connection Description: 3 wire single phase input (L1, L2, G)
- Recommended Electrical Service: 50A
- Input Phase: Single-Phase
- Full Load Runtime (min.): 5.5 min. (7200w)
- Half Load Runtime (min.): 13.5 min. (3600w)
- Expandable Battery Runtime: Supports extended runtime with optional external battery packs
- External Battery Pack Compatibility: BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH
- DC System Voltage (VDC): 240
- Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 90% (typical, full load discharge)
- Battery Replacement Description: Hot-swappable, user replaceable external battery packs
- Expandable Runtime: Yes
- Voltage Regulation Description: 2% output voltage regulation in standard online, double-conversion mode
- Overvoltage Correction: Corrects overvoltages up to 300V
- Undervoltage Correction: Corrects undervoltages as low as 100V
- Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
- Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
- Alarm Cancel Operation: Alarm cancel switch
- Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
- LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
- UPS AC Suppression Response Time: Instantaneous
- EMI / RFI AC Noise Suppression: Yes
- Output Isolation Transformer: 120V output is isolation transformer protected
- Included Mounting Accessory Description: 3 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included
- Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD)
- Optional Mounting Accessory Notes: 3 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module, battery pack and transformer
- Primary Form Factor: Rackmount
- UPS Power Module Dimensions (hwd, in.): 5.14 x 17.5 x 25.82
- Rack Height (U Spaces): 8
- Maximum Device Depth (in.): 32.5
- Minimum Required Rack Depth (inches): 37.5
- UPS Power Module Weight (lbs.): 43
- UPS Power Module Weight (kg): 19.50
- UPS Dimensions Details: Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
- Stepdown Transformer Dimensions (hwd / in.): 3.5 x 17.5 x 20.8
- Stepdown Transformer Weight (lbs.): 57
- Included Battery Pack Dimensions (hwd / in.): 5.25 x 17.5 x 25
- Included Battery Pack Weight (lbs.): 158.7
- UPS Shipping Dimensions (hwd / in.): 49.25 x 23 x 31.5
- Shipping Weight (lbs.): 402.2
- Cooling Method: Fan
- UPS Housing Material: Steel
- Minimum Required Rack Depth (mm): 952
- Stepdown Transformer Height (mm): 89
- Stepdown Transformer Width (mm): 444
- Stepdown Transformer Depth (mm): 528
- Primary UPS Height (mm): 131
- Primary UPS Width (mm): 444
- Primary UPS Depth (mm): 656
- Shipping Height (mm): 1251
- Shipping Width (mm): 584
- Shipping Depth (mm): 800
- Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load): 2732
- AC Economy Mode BTU / Hr. (Full Load): 1024
- Battery Mode BTU / Hr. (Full Load): 2432
- AC Mode Efficiency Rating (100% Load): 91%
- AC Economy Mode Efficiency Rating (100% Load): 96%
- Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
- Audible Noise: 60 dBA at front side 1 meter
- Operating Elevation (msnm): 0-3000 m
- Communications Interface: USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
- Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
- Network Monitoring Port Description: Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
- PowerAlert Software: For local monitoring via the UPSs built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable: USB, DB9 serial and EPO cables included
- WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
- Transfer Time (Economy Mode): 8 ms. typical power failure response in optional economy mode
- Low Voltage Transfer to Battery Power (Setpoint): 100V
- High Voltage Transfer to Battery Power (Setpoint): 300V
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- Economy Mode Operation: Optional economy mode enables high-efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
- High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
- Green Energy-Saving Features: High efficiency economy mode operation; Schedulable daily hours of economy mode operation
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
- UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
- Product Warranty Period (Worldwide): 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance
- Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932517.pdf","title":"Owner's Manual for SmartOnline 5kVA Transformer 932517"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932897.pdf","title":"Owner's Manual for SmartOnline 8kVA-10kVA UPS 932897 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SU8000RT3U1TF-Runtime-Chart-EN.pdf","title":"SU8000RT3U1TF runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932487.PDF","title":"Owner's Manual for BP Battery 932487 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/su8000rt3u-1tf-smartonline-ups-system\/60575","title":"https:\/\/www.tripplite.com\/video\/su8000rt3u-1tf-smartonline-ups-system\/60575"},{"url":"https:https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731","title":"https:\/\/www.tripplite.com\/video\/the-need-for-hot-swappable-ups-systems-demo\/45731"},{"url":"https:https:\/\/www.tripplite.com\/video\/8-10kva-smartonline-ups-hot-swap-demo\/45730","title":"https:\/\/www.tripplite.com\/video\/8-10kva-smartonline-ups-hot-swap-demo\/45730"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/3552","title":"Download images for this product"}]}
- Manufacturer Product URL: https://www.tripplite.com/smartonline-208-120v-8kva-7.2kw-double-conversion-ups-8u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial-bypass-switch-nema-outlets~SU8000RT3U1TF/
- Packaging
- Certifications
- Details: "Overview\nTripp Lite SU8000RT3U1TF 8000VA \/ 8kVA \/ 7200 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations."
- List price: No