Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartOnline 230V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial
$1,438.19

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SUINT3000RTXL3U
Sku:
92082
UPC:
0037332117960
Overview Tripp Lite's SUINT3000RTXL3U UPS System offers complete power conditioning and battery support for critical fileservers and internetworking equipment in a versatile 3U rack/tower configuration. Offers compatibility with 200/208/220/230/240V applications at 50/60Hz. Double conversion power conditioning process removes line noise, voltage fluctuations and frequency variations by converting incoming AC to DC, then back to universally compatible pure sine wave AC output. Standard internal batteries offer seamless support of connected equipment during power failures with zero transfer time. Support through extended power failures is available with the addition of 2U rack/tower compatible battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible). Maintains continuous output over an input range of 160 to 275V without depleting battery reserves. Brownout support extends to 130V when loaded to 70% or less. Intelligent DB9 monitoring port works with PowerAlert software, available via free download, for unattended shutdown and remote monitoring of UPS and site power conditions. Network accessory slot houses optional network management card options. Includes 10 outlets total, 8 of which are arranged in two customized load management banks that can be remotely powered off and on via software interface to reboot locked equipment or extend battery runtime for more critical equipment by shedding non-essential loads. C20 input connection accepts a variety of detachable cordsets to match country- or site-specific wall receptacles. 3000VA/2400W power-handling ability with full CE rating and Class A EMI/RFI rating supports a wide range of fileservers and internetworking equipment, plus other sensitive loads requiring full-time power conditioning, regulation and battery support. Compatible with Tripp Lite's WatchDog system service software.

Specifications

Additional Information

  • UPC: 0037332117960
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 3000
  • Output kVA Capacity (kVA): 3
  • Output Watt Capacity (Watts): 2400
  • Output kW Capacity (kW): 2.4
  • Output Capacity Details: OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
  • Power Factor: 0.8
  • Crest Factor: 3:1
  • Nominal Output Voltage(s) Supported: 200V; 220V; 230V; 240V
  • Nominal Voltage Details: 230V default
  • Frequency Compatibility: 50 / 60 Hz
  • Frequency Compatibility Details: Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start
  • Output Voltage Regulation (Line Mode): +/- 2%
  • Output Voltage Regulation (Economy Line Mode): +/- 10%
  • Output Voltage Regulation (Battery Mode): +/- 2%
  • Output Receptacles: (8) C13; (2) C19
  • Included Output Power Cables: Includes 1 C19 to C20 and 2 C13 to C14 output power cables
  • Load Management Receptacles: Two switchable four-outlet C13 load banks
  • Output Circuit Breakers: 10A (x2) each breaker protects 4 C13 outlets, C19 is unbreakered
  • Hot-Swap PDU options: PDUBHV20 (2U / 6 C13, 2 C19 outlets)
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Rated input current (Maximum Load): 14.9A (200V),14.3A (208V). 13.1A (220V), 12.6A (230V), 12.1A (240V)
  • Nominal Input Voltage(s) Supported: 200V AC; 220V AC; 230V AC; 240V AC
  • UPS Input Connection Type: C20 inlet
  • UPS Input Connection Description: Supports a variety of user supplied input power cables
  • Input Circuit Breakers: 25A
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 5 min. (2400w)
  • Half Load Runtime (min.): 14 min. (1200w)
  • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
  • External Battery Pack Compatibility: BP72V15-2U(limit 1); BP72V28RT-3U(multi-pack compatible); BP72V18-2US(multi-pack compatible)
  • DC System Voltage (VDC): 72
  • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 80% (typical, full load discharge)
  • Internal UPS Replacement Battery Cartridge: RBC53(quantity 2)
  • Battery Access: Front panel battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: 2% output voltage regulation during overvoltages to 275
  • Undervoltage Correction: 2% output voltage regulation during undervoltages to 156
  • Severe Undervoltage Correction: 2% output voltage regulation during undervoltages to 130 (under 70% load only)
  • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
  • Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
  • LED Indicators: 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
  • UPS AC Suppression Joule Rating: 480
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • Included Mounting Accessory Description: 4 post rackmount installation accessories included
  • Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
  • Primary Form Factor: Rackmount
  • UPS Power Module Dimensions (hwd, in.): 5.25 x 17.5 x 21
  • Rack Height (U Spaces): 3
  • Minimum Required Rack Depth (inches): 32
  • UPS Power Module Weight (lbs.): 74.9
  • UPS Power Module Weight (kg): 33.97
  • UPS Shipping Dimensions (hwd / in.): 13.3 x 23.8 x 25.8
  • Shipping Weight (lbs.): 90.3
  • Cooling Method: Fan
  • UPS Housing Material: Steel
  • Minimum Required Rack Depth (mm): 813
  • Primary UPS Height (mm): 133
  • Primary UPS Width (mm): 444
  • Primary UPS Depth (mm): 533
  • Shipping Height (mm): 338
  • Shipping Width (mm): 605
  • Shipping Depth (mm): 655
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 1117
  • Battery Mode BTU / Hr. (Full Load): 1225
  • AC Mode Efficiency Rating (100% Load): 87%
  • AC Economy Mode Efficiency Rating (100% Load): 94%
  • Audible Noise: 47dBA At Front Side 1 Meter
  • Communications Interface: DB9 Serial; Contact closure; Slot for SNMP/Web interface
  • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
  • Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: DB9 cable included
  • WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
  • Low Voltage Transfer to Battery Power (Setpoint): 160V (100% load), 130V ( <70% load)
  • High Voltage Transfer to Battery Power (Setpoint): 275
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
  • Green Energy-Saving Features: High efficiency economy mode operation
  • UPS Certifications: Tested to UL1778 (USA); CE
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: ""
  • Manufacturer Product URL: https://www.tripplite.com/smartonline-230v-3kva-2.4kw-double-conversion-ups-3u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial~SUINT3000RTXL3U/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite's SUINT3000RTXL3U UPS System offers complete power conditioning and battery support for critical fileservers and internetworking equipment in a versatile 3U rack\/tower configuration. Offers compatibility with 200\/208\/220\/230\/240V applications at 50\/60Hz. Double conversion power conditioning process removes line noise, voltage fluctuations and frequency variations by converting incoming AC to DC, then back to universally compatible pure sine wave AC output. Standard internal batteries offer seamless support of connected equipment during power failures with zero transfer time. Support through extended power failures is available with the addition of 2U rack\/tower compatible battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible). Maintains continuous output over an input range of 160 to 275V without depleting battery reserves. Brownout support extends to 130V when loaded to 70% or less. Intelligent DB9 monitoring port works with PowerAlert software, available via free download, for unattended shutdown and remote monitoring of UPS and site power conditions. Network accessory slot houses optional network management card options. Includes 10 outlets total, 8 of which are arranged in two customized load management banks that can be remotely powered off and on via software interface to reboot locked equipment or extend battery runtime for more critical equipment by shedding non-essential loads. C20 input connection accepts a variety of detachable cordsets to match country- or site-specific wall receptacles. 3000VA\/2400W power-handling ability with full CE rating and Class A EMI\/RFI rating supports a wide range of fileservers and internetworking equipment, plus other sensitive loads requiring full-time power conditioning, regulation and battery support. Compatible with Tripp Lite's WatchDog system service software."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...