Welcome to Blue Square Group

M-F 9:00 A.M.- 5:00 P.M. 866-439-2356

SmartPro 120V 1kVA 750W Medical-Grade Line-Interactive Tower UPS, 4 Outlets, Full Isolation, Expandable Runtime
$689.44

Availability: In stock

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SMART1200XLHG
Sku:
12470
UPC:
0037332116406
Overview Tripp Lites SMART1200XLHG medical-grade UPS system provides dependable battery backup and is fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, making it ideal for use in patient-care vicinities. The 1kVA/750W capacity provides up to 28 minutes of runtime for a half load or 10 minutes for a full load, so you can work through short power failures and perform an orderly system shutdown in a prolonged blackout. Built-in line-interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V to normal 120V nominal output without drawing battery power. The SMART1200XLHGs built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise, while maintaining full AC surge suppression in all modes. This UPS system features four NEMA 5-15R-HG hospital-grade outlets and has a hospital-grade NEMA 5-15P-HG plug with a six-foot cord for flexibility in placement. All four outlets provide both backup protection and surge protection rated to 940 joules. The SMART1200XLHG also features diagnostic LEDs, as well as a USB port and a DB9 serial port that work with Tripp Lites included PowerAlert software for safe, unattended system shutdown and file saves in the event of a prolonged power failure.

Specifications

Additional Information

  • UPC: 0037332116406
  • Manufacturer: TRIPPLITE

  • Specifications
  • Output Volt Amp Capacity (VA): 1000
  • Output kVA Capacity (kVA): 1
  • Output Watt Capacity (Watts): 750
  • Power Factor: 0.8
  • Nominal Output Voltage(s) Supported: 115V; 120V
  • Frequency Compatibility: 60 Hz
  • Output Voltage Regulation (Line Mode): -18%, +8%
  • Output Voltage Regulation (Battery Mode): 115V (+/- 5%)
  • Output Receptacles: (4) 5-15R
  • Output Receptacle Details: Hospital grade output receptacles
  • Output AC Waveform (AC Mode): Sine wave
  • Output AC Waveform (Battery Mode): PWM sine wave
  • Rated input current (Maximum Load): 9.2A
  • Nominal Input Voltage(s) Supported: 120V AC
  • UPS Input Connection Type: 5-15P-HG
  • Input Circuit Breakers: 15A
  • UPS Input Cord Length (ft.): 6
  • Recommended Electrical Service: 15A 120V
  • Input Cord Length (ft.): 6
  • Input Phase: Single-Phase
  • Full Load Runtime (min.): 10 min. (750w)
  • Half Load Runtime (min.): 28 min. (375w)
  • Expandable Battery Runtime: Extended runtime supported via optional external battery packs
  • External Battery Pack Compatibility: BP36V15-2U(limit 1); BP36V27-2US(multi-pack compatible); BP36V42-3U(multi-pack compatible)
  • DC System Voltage (VDC): 36
  • Battery Recharge Rate (Included Batteries): Less than 4.5 hours from 10% to 90%
  • Internal UPS Replacement Battery Cartridge: RBC36SLT
  • Battery Access: Battery access door
  • Battery Replacement Description: Hot-swappable, user replaceable batteries
  • Expandable Runtime: Yes
  • Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
  • Overvoltage Correction: Input voltages between 126 and 143 are reduced by 9%
  • Undervoltage Correction: Input voltages between 96 and 106 are boosted by 10%
  • Severe Undervoltage Correction: Input voltages between 81 and 95 are boosted by 21%
  • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation
  • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
  • Audible Alarm: Factory-muted audible alarm indicates power-failure, overload and low-battery conditions
  • LED Indicators: 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
  • UPS AC Suppression Joule Rating: 940
  • UPS AC Suppression Response Time: Instantaneous
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Joule Rating: 940
  • Output Isolation Transformer: Hospital grade load isolation transformer
  • Leakage Current: Less than 100 microamps
  • Installation Form Factors Supported with Optional Accessories: Wallmount(UPSWM - tower mounting kit)
  • Primary Form Factor: Tower
  • UPS Power Module Dimensions (hwd, in.): 12.5 x 7.5 x 9.5
  • UPS Power Module Weight (lbs.): 45.2
  • UPS Power Module Weight (kg): 20.50
  • UPS Shipping Dimensions (hwd / in.): 18.2 x 11.8 x 13.5
  • Shipping Weight (lbs.): 51
  • Cooling Method: Fan
  • UPS Housing Material: PVC
  • Primary UPS Height (mm): 318
  • Primary UPS Width (mm): 190
  • Primary UPS Depth (mm): 241
  • Shipping Height (mm): 462
  • Shipping Width (mm): 300
  • Shipping Depth (mm): 343
  • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 162.8
  • Battery Mode BTU / Hr. (Full Load): 315.2
  • AC Mode Efficiency Rating (100% Load): 94%
  • Communications Interface: USB; DB9 Serial
  • Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions
  • PowerAlert Software: For local monitoring via the UPSs built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
  • Communications Cable: USB and DB9 serial cabling included
  • Transfer Time: 2-4 milliseconds
  • Low Voltage Transfer to Battery Power (Setpoint): 81
  • High Voltage Transfer to Battery Power (Setpoint): 143
  • Grounding Lug: Grounding lug (equipotential)
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Hot swappable batteries
  • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade)
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932755.pdf","title":"Quick Start Guide for PowerAlert Power Management Software 932755"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/9332C2.pdf","title":"Owner's Manual for Medical-Grade UPS Systems 9332C2"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SMART1200XLHG-Runtime-Chart-EN.pdf","title":"SMART1200XLHG runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Flyer\/Tripp-Lite-Healthcare-Applications-Flyer-EN.pdf","title":"Tripp Lite Healthcare Applications Flyer 95343A (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Healthcare-Power-Solutions-Brochure-1209047-EN.pdf","title":"Global UPS Systems for Healthcare Brochure (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-for-Healthcare-Brochure-EN.pdf","title":"UPS Systems for Healthcare Brochure 95336C (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Healthcare-Medical-Solutions-Brochure-EN.pdf","title":"Healthcare\/Medical Solutions Brochure 953476 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/tripp-lite-healthcare-solutions\/150359","title":"https:\/\/www.tripplite.com\/video\/tripp-lite-healthcare-solutions\/150359"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/63","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/smartpro-120v-1kva-750w-medical-grade-line-interactive-tower-ups-4-outlets-full-isolation-expandable-runtime~SMART1200XLHG/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lites SMART1200XLHG medical-grade UPS system provides dependable battery backup and is fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, making it ideal for use in patient-care vicinities. The 1kVA\/750W capacity provides up to 28 minutes of runtime for a half load or 10 minutes for a full load, so you can work through short power failures and perform an orderly system shutdown in a prolonged blackout.\n\nBuilt-in line-interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V to normal 120V nominal output without drawing battery power. The SMART1200XLHGs built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise, while maintaining full AC surge suppression in all modes.\n\nThis UPS system features four NEMA 5-15R-HG hospital-grade outlets and has a hospital-grade NEMA 5-15P-HG plug with a six-foot cord for flexibility in placement. All four outlets provide both backup protection and surge protection rated to 940 joules.\n\nThe SMART1200XLHG also features diagnostic LEDs, as well as a USB port and a DB9 serial port that work with Tripp Lites included PowerAlert software for safe, unattended system shutdown and file saves in the event of a prolonged power failure."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...