SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9
Specifications
Additional Information
- UPC: 37332123527
- Manufacturer: TRIPPLITE
- Specifications
- Output Volt Amp Capacity (VA): 750
- Output Watt Capacity (Watts): 600
- Output Capacity Details: Output is reduced to 450 watts when used with external battery packs
- Power Factor: 0.8
- Nominal Output Voltage(s) Supported: 110V; 115V; 120V
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 60 Hz
- Output Voltage Regulation (Line Mode): -21%, +8%
- Output Voltage Regulation (Battery Mode): +/- 5%
- Output Receptacles: (6) 5-15R
- Load Management Receptacles: Two switchable two-outlet 5-15R load banks
- Output AC Waveform (AC Mode): Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Rated input current (Maximum Load): 7.5A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type: 5-15P
- Input Circuit Breakers: 10A
- UPS Input Cord Length (ft.): 10
- Recommended Electrical Service: 15A 120V
- Input Phase: Single-Phase
- Full Load Runtime (min.): 8.5 min. (600w)
- Half Load Runtime (min.): 20.7 min. (300w)
- Expandable Battery Runtime: Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility: BP24V15RT2U(limit 1); BP24V28-2U(limit 1); BP24V70-3U(multi-pack compatible); BP24V36-2US(multi-pack compatible)
- DC System Voltage (VDC): 24
- Battery Recharge Rate (Included Batteries): Less than 4.5 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge: See Tripp Lite UPS Replacement battery selector
- Battery Access: Front panel battery access door
- Battery Replacement Description: Hot-swappable, user replaceable batteries
- Expandable Runtime: Yes
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
- Overvoltage Correction: Input voltages between 128 and 147 are reduced by 12%
- Undervoltage Correction: Input voltages between 83 and 107 are boosted by 14%
- Switches: 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
- Alarm Cancel Operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
- Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
- LED Indicators: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
- UPS AC Suppression Joule Rating: 570 joules
- EMI / RFI AC Noise Suppression: Yes
- Included Mounting Accessory Description: 4 post rackmount installation accessories included
- Installation Form Factors Supported with Optional Accessories: 2 post rackmount(2POSTRMKITWM); 2-4 post front rail rackmount(UPSHDEARKIT); Tower(2-9USTAND); Wallmount(2POSTRMKITWM)
- Primary Form Factor: Rackmount
- UPS Power Module Dimensions (hwd, in.): 3.45 x 17.35 x 13.15
- Rack Height (U Spaces): 2
- Minimum Required Rack Depth (inches): 16.2
- UPS Power Module Weight (lbs.): 35.4
- UPS Power Module Weight (kg): 16.06
- UPS Shipping Dimensions (hwd / in.): 7.9 x 22.85 x 19.3
- Shipping Weight (lbs.): 46.4
- Cooling Method: Fan
- UPS Housing Material: Steel
- Minimum Required Rack Depth (mm): 411
- Primary UPS Height (mm): 88
- Primary UPS Width (mm): 441
- Primary UPS Depth (mm): 334
- Shipping Height (mm): 201
- Shipping Width (mm): 580
- Shipping Depth (mm): 490
- Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load): 109
- Battery Mode BTU / Hr. (Full Load): 420
- AC Mode Efficiency Rating (100% Load): 95%
- Communications Interface: USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
- Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; RELAYIOCARD
- Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable: USB and DB9 cabling included
- WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Transfer Time: 4 milliseconds (AC to battery mode), 2 milliseconds (Battery to AC mode)
- Low Voltage Transfer to Battery Power (Setpoint): 83
- High Voltage Transfer to Battery Power (Setpoint): 147
- Grounding Lug: Back panel grounding lug
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Hot swappable batteries
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
- Product Warranty Period (Worldwide): 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
- Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance
- Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/933149.pdf","title":"Owner's Manual for SmartPro 2U Rackmount UPS 933149"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Runtime-Chart\/SMART750RMXL2U-Runtime-Chart-EN.pdf","title":"SMART750RMXL2U runtime chart"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 120v (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/White-Paper\/Common-Power-Problems-and-Power-Protection-Solutions-White-Paper-230v-EN.pdf","title":"Common Power Problems and Power Protection Solutions White Paper 230v (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/UPS-Systems-Brochure-9533B9-EN-120V.PDF","title":"UPS Systems 120V Brochure 953426 (English)"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-buying-guide","title":"UPS Systems Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/single-vs3-phase","title":"Single-Phase vs. 3-Phase Power"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/products\/economy-mode","title":"Economy Mode Explained"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/top-12-questions-when-choosing-a-network-ups","title":"Top 12 Questions to Consider When Choosing UPS Systems for Network\/Server Applications"},{"url":"https:https:\/\/www.tripplite.com\/products\/ups-sizing","title":"UPS Sizing"},{"url":"https:https:\/\/www.tripplite.com\/video\/smart750rmxl2u-line-interactive-ups-system\/60478","title":"https:\/\/www.tripplite.com\/video\/smart750rmxl2u-line-interactive-ups-system\/60478"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/3020","title":"Download images for this product"}]}
- Manufacturer Product URL: https://www.tripplite.com/smartpro-120v-750va-600w-line-interactive-sine-wave-ups-2u-rack-tower-extended-run-snmpwebcard-option-lcd-display-usb-rb9-serial~SMART750RMXL2U/
- Packaging
- Certifications
- Details: "Overview\nTripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 95% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and slot for optional Network Management Card options. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. PowerAlert UPS monitoring software is available via free download. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules."
- List price: No