0037332158383
Overview Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.

Specifications

Additional Information

  • UPC: 0037332158383
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Switched
  • Output Capacity Details: 11.5kW (415/240V), 11.1kW (400/230V), 10.5kW (380/220V) total capacity; 16A max per output phase (L1-L2, L2-L3, L3-L1); 16A max per C19 outlet; 10A max per C13 outlet
  • Frequency Compatibility: 50 Hz; 60 Hz
  • Output Receptacles: (21) C13; (3) C19
  • Output Nominal Voltage: 220 (380V input); 230 (400V input)
  • Overload Protection: n/a
  • Customized Load Management Receptacles: Each outlet is individually controllable via remote interface
  • PDU Input Voltage: 380; 400
  • Recommended Electrical Service: 16A 400/230V with IEC309 16A Red (3P+N+E) outlet
  • Maximum Input Amps: 16
  • PDU Plug Type: IEC-309 16/20A RED (3P+N+E)
  • Input Cord Length (ft.): 3
  • Input Phase: 3-Phase
  • Reported Load Segments: Supports local monitoring of current for each output phase (L1, L2 and L3) and for each output receptacle; BANK "L1" is powered by L1-N (outlets 1-8); BANK "L2" is powered by L2-N (outlets 9-16); BANK "L3" is powered by L3-N (outlets 17-24)
  • Front Panel LCD Display: Digital display reports output load level in amps separately for each output phase and each individual output receptacle; Can also be used to scroll the configured IP address
  • Front Panel LEDs: Set of 3 LEDs (L1, L2, L3) indicate the output load segment the digital current display is reporting; LEDs for L1, L2, L3 will also flash to indicate that the display is reporting current level for one of the outlets in that load bank; One additional LED per output receptacle indicates power ON/OFF status for that outlet
  • Switches: SELECT switch advances the digital display and LED to report power consumption for load segments L1, L2, L3 and for each individual output receptacle (short press); SELECT switch also rotates the local display 90 degrees for overhead power input (long press); SCROLL IP button scrolls the configured IP address (long press)
  • Shipping Dimensions (hwd / in.): 75.4 x 6.6 x 9.3
  • Shipping Weight (lbs.): 19.5
  • Unit Dimensions (hwd / in.): 70 x 2.19 x 3.26
  • Unit Weight (lbs.): 12.4
  • Material of Construction: Metal
  • Form Factors Supported: Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
  • PDU Form Factor: 0U; Vertical
  • Storage Temperature Range: 5 to 122F (-15 to 50C)
  • Relative Humidity: 5 to 95% non-condensing
  • Operating Elevation (ft.): 0-10,000
  • Operating Elevation (msnm): 0-3000
  • SNMP Compatibility: Yes, pre-installed SNMPWEBCARD provides remote monitoring via web, telnet, SSH and SNMP management systems
  • TAA Compliant Option: TAA Compliant Version Available - Order Tripp Lite PDU3XVSR3G16TAA
  • Certifications: Tested to CE (EN 60950-1), Class A (Emissions), RoHS (Hazardous Substances)
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/932906.pdf","title":"Owner's Manual for High Voltage 3-Phase PDU 932906 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/PDU3XVSR3G16-PDU3XVSR10G16-Submittal-Drawing-EN.pdf","title":"Submittal Drawings"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/230V-PDU-Specification-Brochure-EN.pdf","title":"230V Power Distribution Unit (PDU) Specification Brochure 9533FF (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/4726","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/11kw-3-phase-switched-pdu-220-230v-21-c13-3-c19-iec-309-16a-red-380-400v-input-3ft-cord-0u-vertical~PDU3XVSR3G16/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite 3 phase Switched PDU \/ Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web\/network interface to warn of potential overloads before critical IT mains or branch breakers trip."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...