16.2kW 3-Phase Switched PDU, 208V Outlets (6 C13 & 12 C19), IEC-309 60A Blue, 6ft Cord, 0U Vertical, TAA
$1,379.99

Availability: Sold out

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PDU3VSR6G60A
Sku:
618316
UPC:
37332172112
Overview Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker bank and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor).

Specifications

Additional Information

  • UPC: 37332172112
  • Manufacturer: TRIPPLITE

  • Specifications
  • PDU Type: Switched
  • Output Capacity Details: 16.2kW (208V) total capacity; 26A max per output phase (L1-L2, L2-L3, L3-L1); 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
  • Frequency Compatibility: 50 / 60 Hz
  • Output Receptacles: (6) C13; (12) C19
  • Output Nominal Voltage: 208
  • Overload Protection: 6 20A circuit breakers, 1 per outlet bank
  • Customized Load Management Receptacles: Each outlet is individually controllable via remote interface
  • PDU Input Voltage: 208
  • Recommended Electrical Service: 60A 208V with IEC309 60A Blue (3P+E) outlet
  • Maximum Input Amps: 45
  • PDU Plug Type: IEC-309 60A BLUE (3P+E)
  • Input Cord Length (ft.): 6
  • Input Phase: 3-Phase
  • Reported Load Segments: Reports input current per phase (L1, L2, L3), plus output current for each output load bank (B1-B6) and individual output receptacle (1-18); Outlets are color-coded and labelled for phase and load bank identification; L1-L2 feeds black outlets (B1, B4); L2-L3 feeds dark-gray outlets (B2, B5); L3-L1 feeds light-gray outlets (B3, B6)
  • Front Panel LCD Display: Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature* and Humidity* information (*requires ENIVIROSENSE option); Small digital display provides detail on the measurement the large display is reporting: Input-phase (L#), Load bank (B#), Sensor (S#), Outlet (##), Load unbalance % (UB), Output power (OP)
  • Front Panel LEDs: Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH); One additional LED for each output receptacle offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip)
  • Switches: Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options; Additional MODE button advances the LEDs to view the next measurement
  • Shipping Dimensions (hwd / in.): 75.9 x 9.7 x 7.1
  • Shipping Weight (lbs.): 26.7
  • Unit Dimensions (hwd / in.): 70 x 2.17 x 2.49
  • Unit Weight (lbs.): 20.7
  • Material of Construction: Metal
  • Form Factors Supported: Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
  • PDU Form Factor: 0U; Vertical
  • Relative Humidity: 5 to 95% non-condensing
  • Operating Elevation (msnm): 0 to 3000m (0 to 10,000 ft.)
  • SNMP Compatibility: Yes, pre-installed SNMPWEBCARD provides remote monitoring via web, telnet, SSH and SNMP management systems
  • Certifications: Tested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
  • Product Warranty Period (Worldwide): 2-year limited warranty

  • Downloads: {"documents":[{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/933179.pdf","title":"Installation Guide for SNMPWEBCARD 933179"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/9332B8.pdf","title":"Owner's Manual for 3-Phase Switched 0U PDUs 93-32B8 (Multi-language)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/techdoc\/Owners-Manual\/93328B.pdf","title":"User's Guide for SNMPWEBCARD Firmware Version 12.06.0062 Rev. 3 93328B"},{"url":"https:https:\/\/www.tripplite.com\/shared\/other_downloads\/submittal\/PDU3VSR6G60A-3-Phased-PDU-Submittal-Drawing-EN.pdf","title":"Submittal Drawings"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Brochure-953351-EN-120V.pdf","title":"120V Power Distribution Unit (PDU) Brochure 9534B2 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Network-Grade-PDU-Brochure-9533D6-English-230V.pdf","title":"230V Power Distribution Unit (PDU) Brochure 9533F9 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Tripp-Lite-Integrated-Solutions-Brochure-9533AD-EN-Domestic.pdf","title":"Integrated Solutions Brochure 953479 (English)"},{"url":"https:https:\/\/www.tripplite.com\/shared\/literature\/Brochure\/Power-Distribution-Unit-PDU-Specifications-Brochure-EN.pdf","title":"120V Power Distribution Unit (PDU) Models and Specifications List 9534B4 (English)"}],"miscellanous":[{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-buying-guide","title":"PDU Buying Guide"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-installation","title":"PDU Installation Options"},{"url":"https:https:\/\/www.tripplite.com\/products\/custom-products","title":"Custom Products from Tripp Lite Are One Call Away"},{"url":"https:https:\/\/www.tripplite.com\/support\/outlet-plug-types","title":"Outlet Plug Types"},{"url":"https:https:\/\/www.tripplite.com\/support\/articles\/articleid\/seven-steps-to-choosing-the-right-single-phase-or-3-phase-pdu","title":"7 Steps to Choosing the Right Single-Phase or 3-Phase PDU"},{"url":"https:https:\/\/www.tripplite.com\/products\/pdu-types\/cid\/11","title":"PDU Types"},{"url":"https:https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627","title":"https:\/\/www.tripplite.com\/video\/how-to-choose-a-pdu:-switched-pdus\/63627"},{"url":"https:https:\/\/www.tripplite.com\/resellers\/imageSearch\/mid\/5543","title":"Download images for this product"}]}
  • Manufacturer Product URL: https://www.tripplite.com/16.2kw-3-phase-switched-pdu-208v-outlets-6-c13-12-c19-iec-309-60a-blue-6ft-cord-0u-vertical-taa~PDU3VSR6G60A/
  • Packaging

  • Certifications

  • Details: "Overview\nTripp Lite 3 phase Switched PDU \/ Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. Built-in local digital display and remote web\/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker bank and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)."
  • List price: No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

 
  Loading...